[PATCH v2 09/32] KVM: VMX: Use vpid_sync_context() directly when possible
From: Sean Christopherson
Date: Tue Mar 17 2020 - 00:54:59 EST
Use vpid_sync_context() directly for flows that run if and only if
enable_vpid=1, or more specifically, nested VMX flows that are gated by
vmx->nested.msrs.secondary_ctls_high.SECONDARY_EXEC_ENABLE_VPID being
set, which is allowed if and only if enable_vpid=1. Because these flows
call __vmx_flush_tlb() with @invalidate_gpa=false, the if-statement that
decides between INVEPT and INVVPID will always go down the INVVPID path,
i.e. call vpid_sync_context() because
"enable_ept && (invalidate_gpa || !enable_vpid)" always evaluates false.
This helps pave the way toward removing @invalidate_gpa and @vpid from
__vmx_flush_tlb() and its callers.
Opportunstically drop unnecessary brackets in handle_invvpid() around an
affected __vmx_flush_tlb()->vpid_sync_context() conversion.
No functional change intended.
Reviewed-by: Miaohe Lin <linmiaohe@xxxxxxxxxx>
Reviewed-by: Vitaly Kuznetsov <vkuznets@xxxxxxxxxx>
Reviewed-by: Paolo Bonzini <pbonzini@xxxxxxxxxx>
Signed-off-by: Sean Christopherson <sean.j.christopherson@xxxxxxxxx>
---
arch/x86/kvm/vmx/nested.c | 12 ++++++------
1 file changed, 6 insertions(+), 6 deletions(-)
diff --git a/arch/x86/kvm/vmx/nested.c b/arch/x86/kvm/vmx/nested.c
index 7bd13d207199..cc36e8da215b 100644
--- a/arch/x86/kvm/vmx/nested.c
+++ b/arch/x86/kvm/vmx/nested.c
@@ -2481,7 +2481,7 @@ static int prepare_vmcs02(struct kvm_vcpu *vcpu, struct vmcs12 *vmcs12,
if (nested_cpu_has_vpid(vmcs12) && nested_has_guest_tlb_tag(vcpu)) {
if (vmcs12->virtual_processor_id != vmx->nested.last_vpid) {
vmx->nested.last_vpid = vmcs12->virtual_processor_id;
- __vmx_flush_tlb(vcpu, nested_get_vpid02(vcpu), false);
+ vpid_sync_context(nested_get_vpid02(vcpu));
}
} else {
/*
@@ -5251,21 +5251,21 @@ static int handle_invvpid(struct kvm_vcpu *vcpu)
is_noncanonical_address(operand.gla, vcpu))
return nested_vmx_failValid(vcpu,
VMXERR_INVALID_OPERAND_TO_INVEPT_INVVPID);
- if (cpu_has_vmx_invvpid_individual_addr()) {
+ if (cpu_has_vmx_invvpid_individual_addr())
__invvpid(VMX_VPID_EXTENT_INDIVIDUAL_ADDR,
vpid02, operand.gla);
- } else
- __vmx_flush_tlb(vcpu, vpid02, false);
+ else
+ vpid_sync_context(vpid02);
break;
case VMX_VPID_EXTENT_SINGLE_CONTEXT:
case VMX_VPID_EXTENT_SINGLE_NON_GLOBAL:
if (!operand.vpid)
return nested_vmx_failValid(vcpu,
VMXERR_INVALID_OPERAND_TO_INVEPT_INVVPID);
- __vmx_flush_tlb(vcpu, vpid02, false);
+ vpid_sync_context(vpid02);
break;
case VMX_VPID_EXTENT_ALL_CONTEXT:
- __vmx_flush_tlb(vcpu, vpid02, false);
+ vpid_sync_context(vpid02);
break;
default:
WARN_ON_ONCE(1);
--
2.24.1