RE: [PATCH 3/3] watchdog: da9062: No need to ping manually before setting timeout
From: Adam Thomson
Date: Wed Apr 01 2020 - 06:20:42 EST
On 26 March 2020 15:02, Stefan Riedmueller wrote:
> There is actually no need to ping the watchdog before disabling it
> during timeout change. Disabling the watchdog already takes care of
> resetting the counter.
>
> This fixes an issue during boot when the userspace watchdog handler takes
> over and the watchdog is already running. Opening the watchdog in this case
> leads to the first ping and directly after that without the required
> heartbeat delay a second ping issued by the set_timeout call. Due to the
> missing delay this resulted in a reset.
>
> Signed-off-by: Stefan Riedmueller <s.riedmueller@xxxxxxxxx>
Thanks for the update:
Reviewed-by: Adam Thomson <Adam.Thomson.Opensource@xxxxxxxxxxx>
> ---
> drivers/watchdog/da9062_wdt.c | 5 -----
> 1 file changed, 5 deletions(-)
>
> diff --git a/drivers/watchdog/da9062_wdt.c b/drivers/watchdog/da9062_wdt.c
> index 6d81b1276b87..c5bd075c8b14 100644
> --- a/drivers/watchdog/da9062_wdt.c
> +++ b/drivers/watchdog/da9062_wdt.c
> @@ -66,11 +66,6 @@ static int da9062_wdt_update_timeout_register(struct
> da9062_watchdog *wdt,
> unsigned int regval)
> {
> struct da9062 *chip = wdt->hw;
> - int ret;
> -
> - ret = da9062_reset_watchdog_timer(wdt);
> - if (ret)
> - return ret;
>
> regmap_update_bits(chip->regmap,
> DA9062AA_CONTROL_D,
> --
> 2.23.0