Just to be clear, syncpt max value increment happens first and syncpt trigger condition is programmed. hw syncpt increment happens based on HW events.
On 4/6/20 9:29 AM, Dmitry Osipenko wrote:
External email: Use caution opening links or attachments
06.04.2020 19:12, Sowjanya Komatineni ÐÐÑÐÑ:
On 4/6/20 9:05 AM, Dmitry Osipenko wrote:My point is that hardware is stopped only after being reset, until then
External email: Use caution opening links or attachmentsThere is possibility of timeout to happen any time even during the
06.04.2020 18:35, Sowjanya Komatineni ÐÐÑÐÑ:
...
It's wrong to touch sync point while hardware is active and it's activeupstream host1x driver don't have API to reset or to equalize max value+ÂÂÂÂ /* wait for syncpt counter to reach frame start eventWhy incrementing is done while hardware is still active?
threshold */
+ÂÂÂÂ err = host1x_syncpt_wait(chan->frame_start_sp, thresh,
+ TEGRA_VI_SYNCPT_WAIT_TIMEOUT, &value);
+ÂÂÂÂ if (err) {
+ÂÂÂÂÂÂÂÂÂÂÂÂ dev_err(&chan->video.dev,
+ÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂÂ "frame start syncpt timeout: %d\n", err);
+ÂÂÂÂÂÂÂÂÂÂÂÂ /* increment syncpoint counter for timedout events */
+ host1x_syncpt_incr(chan->frame_start_sp);
The sync point's state needs to be completely reset after resetting
hardware. But I don't think that the current upstream host1x driver
supports doing that, it's one of the known-long-standing problems of
the
host1x driver.
At least the sp->max_val incrementing should be done based on the
actual
syncpoint value and this should be done after resetting hardware.
with min/load value.
So to synchronize missed event, incrementing HW syncpt counter.
This should not impact as we increment this in case of missed events
only.
until being reset.
You should re-check the timeout after hw resetting and manually put the
syncpoint counter back into sync only if needed.
capture also and is not related to hw reset.
Manual synchronization is needed when timeout of any frame events happen
otherwise all subsequence frames will timeout due to mismatch in event
counters.
you should assume that sync point could be incremented by HW at any time.
And if this happens that HW increments sync point after the timeout,
then the sync point counter should become out-of-sync in yours case,
IIUC. Because host1x_syncpt_incr() doesn't update the cached counter.
We wait for enough time based on frame rate for syncpt increment to happen and if it doesn't happen by then definitely its missed event and we increment HW syncpoint for this timed event.
cached value gets updated during syncpt wait for subsequent event.
syncpt increment happens for all subsequent frame events during video capture.