Hi Suzuki,
Thanks for looking into this issue.
On 2020-04-07 15:54, Suzuki K Poulose wrote:
On 04/07/2020 10:46 AM, Sai Prakash Ranjan wrote:
There seems to be two replicators back to back here. What is connected
to the other output of both of them ? Are there any TPIUs ? What happens
if you choose a sink on the other end of "swao_replicator" (ETB ?)
The other outport of swao replicator is connected to EUD which is a
QCOM specific HW which can be used as a sink like USB.
And the other outport of other replicator(replicator_out) is connected to
TPIU.
After boot, what do the idfilter registers read for both the replicators ?
Added some prints in replicator_probe.
Âreplicator probe ret=-517 devname=6046000.replicator idfilter0=0x0 idfilter1=0x0
Âreplicator probe ret=0 devname=6b06000.replicator idfilter0=0xff idfilter1=0xff
Âreplicator probe ret=0 devname=6046000.replicator idfilter0=0xff idfilter1=0xff