[PATCH 1/5] dt-bindings: clock: Convert i.MX6Q clock to json-schema

From: Anson Huang
Date: Thu Apr 16 2020 - 00:34:43 EST


Convert the i.MX6Q clock binding to DT schema format using json-schema.

Signed-off-by: Anson Huang <Anson.Huang@xxxxxxx>
---
.../devicetree/bindings/clock/imx6q-clock.txt | 41 -------------
.../devicetree/bindings/clock/imx6q-clock.yaml | 69 ++++++++++++++++++++++
2 files changed, 69 insertions(+), 41 deletions(-)
delete mode 100644 Documentation/devicetree/bindings/clock/imx6q-clock.txt
create mode 100644 Documentation/devicetree/bindings/clock/imx6q-clock.yaml

diff --git a/Documentation/devicetree/bindings/clock/imx6q-clock.txt b/Documentation/devicetree/bindings/clock/imx6q-clock.txt
deleted file mode 100644
index 13d36d4..0000000
--- a/Documentation/devicetree/bindings/clock/imx6q-clock.txt
+++ /dev/null
@@ -1,41 +0,0 @@
-* Clock bindings for Freescale i.MX6 Quad
-
-Required properties:
-- compatible: Should be "fsl,imx6q-ccm"
-- reg: Address and length of the register set
-- interrupts: Should contain CCM interrupt
-- #clock-cells: Should be <1>
-
-Optional properties:
-- fsl,pmic-stby-poweroff: Configure CCM to assert PMIC_STBY_REQ signal
- on power off.
- Use this property if the SoC should be powered off by external power
- management IC (PMIC) triggered via PMIC_STBY_REQ signal.
- Boards that are designed to initiate poweroff on PMIC_ON_REQ signal should
- be using "syscon-poweroff" driver instead.
-- clocks: list of clock specifiers, must contain an entry for each entry
- in clock-names
-- clock-names: valid names are "osc", "ckil", "ckih1", "anaclk1" and "anaclk2"
-
-The clock consumer should specify the desired clock by having the clock
-ID in its "clocks" phandle cell. See include/dt-bindings/clock/imx6qdl-clock.h
-for the full list of i.MX6 Quad and DualLite clock IDs.
-
-Examples:
-
-#include <dt-bindings/clock/imx6qdl-clock.h>
-
-clks: ccm@20c4000 {
- compatible = "fsl,imx6q-ccm";
- reg = <0x020c4000 0x4000>;
- interrupts = <0 87 0x04 0 88 0x04>;
- #clock-cells = <1>;
-};
-
-uart1: serial@2020000 {
- compatible = "fsl,imx6q-uart", "fsl,imx21-uart";
- reg = <0x02020000 0x4000>;
- interrupts = <0 26 0x04>;
- clocks = <&clks IMX6QDL_CLK_UART_IPG>, <&clks IMX6QDL_CLK_UART_SERIAL>;
- clock-names = "ipg", "per";
-};
diff --git a/Documentation/devicetree/bindings/clock/imx6q-clock.yaml b/Documentation/devicetree/bindings/clock/imx6q-clock.yaml
new file mode 100644
index 0000000..084d4f0
--- /dev/null
+++ b/Documentation/devicetree/bindings/clock/imx6q-clock.yaml
@@ -0,0 +1,69 @@
+# SPDX-License-Identifier: GPL-2.0
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/clock/imx6q-clock.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Clock bindings for Freescale i.MX6 Quad
+
+maintainers:
+ - Anson Huang <Anson.Huang@xxxxxxx>
+
+properties:
+ compatible:
+ const: fsl,imx6q-ccm
+
+ reg:
+ maxItems: 1
+
+ interrupts:
+ minItems: 1
+ maxItems: 2
+
+ '#clock-cells':
+ const: 1
+
+ clocks:
+ items:
+ - description: 24m osc
+ - description: 32k osc
+ - description: ckih1 clock input
+ - description: anaclk1 clock input
+ - description: anaclk2 clock input
+
+ clock-names:
+ items:
+ - const: osc
+ - const: ckil
+ - const: ckih1
+ - const: anaclk1
+ - const: anaclk2
+
+ fsl,pmic-stby-poweroff:
+ $ref: /schemas/types.yaml#/definitions/flag
+ description: |
+ Use this property if the SoC should be powered off by external power
+ management IC (PMIC) triggered via PMIC_STBY_REQ signal.
+ Boards that are designed to initiate poweroff on PMIC_ON_REQ signal should
+ be using "syscon-poweroff" driver instead.
+
+required:
+ - compatible
+ - reg
+ - interrupts
+ - '#clock-cells'
+
+examples:
+ # Clock Control Module node:
+ - |
+ #include <dt-bindings/interrupt-controller/arm-gic.h>
+
+ clks: clock-controller@20c4000 {
+ compatible = "fsl,imx6q-ccm";
+ reg = <0x020c4000 0x4000>;
+ interrupts = <0 87 IRQ_TYPE_LEVEL_HIGH>,
+ <0 88 IRQ_TYPE_LEVEL_HIGH>;
+ #clock-cells = <1>;
+ };
+
+...
--
2.7.4