EXTERNAL EMAIL: Do not click links or open attachments unless you know the content is safe
Introduce a ingress frame gate control flow action.
Tc gate action does the work like this:
Assume there is a gate allow specified ingress frames can be passed at
specific time slot, and be dropped at specific time slot. Tc filter
chooses the ingress frames, and tc gate action would specify what slot
does these frames can be passed to device and what time slot would be
dropped.
Tc gate action would provide an entry list to tell how much time gate
keep open and how much time gate keep state close. Gate action also
assign a start time to tell when the entry list start. Then driver would
repeat the gate entry list cyclically.
For the software simulation, gate action requires the user assign a time
clock type.
Below is the setting example in user space. Tc filter a stream source ip
address is 192.168.0.20 and gate action own two time slots. One is last
200ms gate open let frame pass another is last 100ms gate close let
frames dropped. When the frames have passed total frames over 8000000
bytes, frames will be dropped in one 200000000ns time slot.
tc qdisc add dev eth0 ingress
tc filter add dev eth0 parent ffff: protocol ip \flower src_ip 192.168.0.20 \
action gate index 2 clockid CLOCK_TAI \
sched-entry open 200000000 -1 8000000 \
sched-entry close 100000000 -1 -1