[PATCH] iio: bmp280: fix compensation of humidity

From: Andreas Klinger
Date: Mon Apr 27 2020 - 10:01:11 EST


Output of humidity compensation is limited to the range between 0 and 100
percent. Add this to the compensation formula as described in the datasheet
chapter 4.2.3.

Signed-off-by: Andreas Klinger <ak@xxxxxxxxxxxxx>
---
drivers/iio/pressure/bmp280-core.c | 3 +++
1 file changed, 3 insertions(+)

diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index 29c209cc1108..ac9ef1b63b07 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -271,6 +271,9 @@ static u32 bmp280_compensate_humidity(struct bmp280_data *data,
+ (s32)2097152) * calib->H2 + 8192) >> 14);
var -= ((((var >> 15) * (var >> 15)) >> 7) * (s32)calib->H1) >> 4;

+ var = var < 0 ? 0 : var;
+ var = var > 419430400 ? 419430400 : var;
+
return var >> 12;
};

--
2.20.1