Re: [PATCH net-next v3] net: phy: micrel: add phy-mode support for the KSZ9031 PHY
From: Oleksij Rempel
Date: Wed May 06 2020 - 00:51:40 EST
Hi Grygorii,
On Tue, May 05, 2020 at 09:26:46PM +0300, Grygorii Strashko wrote:
>
>
> On 22/04/2020 10:21, Oleksij Rempel wrote:
> > Add support for following phy-modes: rgmii, rgmii-id, rgmii-txid, rgmii-rxid.
> >
> > This PHY has an internal RX delay of 1.2ns and no delay for TX.
> >
> > The pad skew registers allow to set the total TX delay to max 1.38ns and
> > the total RX delay to max of 2.58ns (configurable 1.38ns + build in
> > 1.2ns) and a minimal delay of 0ns.
> >
> > According to the RGMII v1.3 specification the delay provided by PCB traces
> > should be between 1.5ns and 2.0ns. The RGMII v2.0 allows to provide this
> > delay by MAC or PHY. So, we configure this PHY to the best values we can
> > get by this HW: TX delay to 1.38ns (max supported value) and RX delay to
> > 1.80ns (best calculated delay)
> >
> > The phy-modes can still be fine tuned/overwritten by *-skew-ps
> > device tree properties described in:
> > Documentation/devicetree/bindings/net/micrel-ksz90x1.txt
> >
> > Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
> > ---
> > changes v3:
> > - change delay on RX line to 1.80ns
> > - add warning if *-skew-ps properties are used together with not rgmii
> > mode.
> >
> > changes v2:
> > - change RX_ID value from 0x1a to 0xa. The overflow bit was detected by
> > FIELD_PREP() build check.
> > Reported-by: kbuild test robot <lkp@xxxxxxxxx>
> >
> > drivers/net/phy/micrel.c | 128 +++++++++++++++++++++++++++++++++++++--
> > 1 file changed, 123 insertions(+), 5 deletions(-)
> >
>
> This patch broke networking on at least 5 TI boards:
> am572x-idk
> am571x-idk
> am43xx-hsevm
> am43xx-gpevm
> am437x-idk
>
> am57xx I can fix.
>
> am437x need to investigate.
Please try:
phy-mode = "rgmii-txid"
I assume your boards are using "rgmii" which should be used only if you
boards have extra long clk traces.
Regards,
Oleksij
--
Pengutronix e.K. | |
Steuerwalder Str. 21 | http://www.pengutronix.de/ |
31137 Hildesheim, Germany | Phone: +49-5121-206917-0 |
Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |