Am 2020-05-06 11:01, schrieb Matthias May:
I've worked with this PHY quite often and we've hacked together some
support for the CDT in uboot.

Have you done any tests with the cable on the other side being plugged in?

yes


With the cable being plugged in, we something (1 out of 10 or so)
observed that the test returns with a failure.
--> AT803X_CDT_STATUS_STAT_FAIL in AT803X_CDT_STATUS

Often you get the correct result if you simply try again. Sometimes
however it gets into a "stuck" state where it just
returns FAIL for ~3~10 seconds. After some that it seems to recover
and gets the correct result again.

its actually pretty stable for the following sequence (see also code
above):

restart AN -> wait 1.5s -> start test

Only thing I've noticed is that if you perform the test without
waiting for the AN to complete beforehand there might be some
failed states. Seems like the "restart an" doesn't work while
AN is still running. But that seems to be the link partner
who disturbs the measurement.
And it seems that AN is a requirement to do successful testing
(or to silence the link partner I guess).

-michael