[PATCH 4.4 228/312] power: bq27xxx: fix reading for bq27000 and bq27010

From: Greg Kroah-Hartman
Date: Fri May 08 2020 - 09:13:49 EST


From: H. Nikolaus Schaller <hns@xxxxxxxxxxxxx>

commit 549d7b317c761dbf4ed0c2945aec3acc9ca7ae14 upstream.

bug: the driver reports funny capacity values:

root@letux:/sys/class/power_supply/bq27000-battery# cat uevent
POWER_SUPPLY_NAME=bq27000-battery
POWER_SUPPLY_STATUS=Charging
POWER_SUPPLY_PRESENT=1
POWER_SUPPLY_VOLTAGE_NOW=3702000
POWER_SUPPLY_CURRENT_NOW=-464635
POWER_SUPPLY_CAPACITY=1536 <- over 100% is magic
POWER_SUPPLY_CAPACITY_LEVEL=Normal
POWER_SUPPLY_TEMP=311
POWER_SUPPLY_TIME_TO_FULL_NOW=10440
POWER_SUPPLY_TECHNOLOGY=Li-ion
POWER_SUPPLY_CHARGE_FULL=805450
POWER_SUPPLY_CHARGE_NOW=1068
POWER_SUPPLY_CHARGE_FULL_DESIGN=8844998 <- battery has just 1200 mAh
POWER_SUPPLY_CYCLE_COUNT=21
POWER_SUPPLY_ENERGY_NOW=0
POWER_SUPPLY_POWER_AVG=0
POWER_SUPPLY_HEALTH=Good
POWER_SUPPLY_MANUFACTURER=Texas Instruments

reason: the state of charge and the design capacity register are single
byte only. The design capacity returns the higer order byte.

tested: GTA04 with Openmoko/FIC HF08x battery (using hdq)

Fixes: d74534c27775 ("power: bq27xxx_battery: Add support for additional bq27xxx family devices")
Signed-off-by: H. Nikolaus Schaller <hns@xxxxxxxxxxxxx>
Acked-by: Andrew F. Davis <afd@xxxxxx>
Reviewed-by: Pali RohÃr <pali.rohar@xxxxxxxxx>
Signed-off-by: Sebastian Reichel <sre@xxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
drivers/power/bq27xxx_battery.c | 12 +++++++++---
1 file changed, 9 insertions(+), 3 deletions(-)

--- a/drivers/power/bq27xxx_battery.c
+++ b/drivers/power/bq27xxx_battery.c
@@ -471,7 +471,10 @@ static int bq27xxx_battery_read_soc(stru
{
int soc;

- soc = bq27xxx_read(di, BQ27XXX_REG_SOC, false);
+ if (di->chip == BQ27000 || di->chip == BQ27010)
+ soc = bq27xxx_read(di, BQ27XXX_REG_SOC, true);
+ else
+ soc = bq27xxx_read(di, BQ27XXX_REG_SOC, false);

if (soc < 0)
dev_dbg(di->dev, "error reading State-of-Charge\n");
@@ -536,7 +539,10 @@ static int bq27xxx_battery_read_dcap(str
{
int dcap;

- dcap = bq27xxx_read(di, BQ27XXX_REG_DCAP, false);
+ if (di->chip == BQ27000 || di->chip == BQ27010)
+ dcap = bq27xxx_read(di, BQ27XXX_REG_DCAP, true);
+ else
+ dcap = bq27xxx_read(di, BQ27XXX_REG_DCAP, false);

if (dcap < 0) {
dev_dbg(di->dev, "error reading initial last measured discharge\n");
@@ -544,7 +550,7 @@ static int bq27xxx_battery_read_dcap(str
}

if (di->chip == BQ27000 || di->chip == BQ27010)
- dcap *= BQ27XXX_CURRENT_CONSTANT / BQ27XXX_RS;
+ dcap = (dcap << 8) * BQ27XXX_CURRENT_CONSTANT / BQ27XXX_RS;
else
dcap *= 1000;