[PATCHv1 14/19] power: supply: sbs-battery: fix idle battery status

From: Sebastian Reichel
Date: Wed May 13 2020 - 14:57:09 EST


A battery, that is neither charged, nor discharged is not
always Full. If the charger is disabled for other reasons
it might simply be idle and should be marked accordingly.

Signed-off-by: Sebastian Reichel <sebastian.reichel@xxxxxxxxxxxxx>
---
drivers/power/supply/sbs-battery.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/power/supply/sbs-battery.c b/drivers/power/supply/sbs-battery.c
index 2a2b926ad75c..e3c685b2c247 100644
--- a/drivers/power/supply/sbs-battery.c
+++ b/drivers/power/supply/sbs-battery.c
@@ -354,9 +354,9 @@ static int sbs_status_correct(struct i2c_client *client, int *intval)

ret = (s16)ret;

- /* Not drawing current means full (cannot be not charging) */
- if (ret == 0)
- *intval = POWER_SUPPLY_STATUS_FULL;
+ /* Not drawing current -> not charging (i.e. idle) */
+ if (*intval != POWER_SUPPLY_STATUS_FULL && ret == 0)
+ *intval = POWER_SUPPLY_STATUS_NOT_CHARGING;

if (*intval == POWER_SUPPLY_STATUS_FULL) {
/* Drawing or providing current when full */
--
2.26.2