[PATCH net-next 3/5] net: hns3: modify an incorrect error log in hclge_mbx_handler()
From: Huazhong Tan
Date: Thu May 14 2020 - 08:43:20 EST
When handling HCLGE_MBX_GET_LINK_STATUS, PF will return the link
status to the VF, so the error log of hclge_get_link_info() is
incorrect.
Reported-by: Jian Shen <shenjian15@xxxxxxxxxx>
Signed-off-by: Huazhong Tan <tanhuazhong@xxxxxxxxxx>
---
drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mbx.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mbx.c b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mbx.c
index ac70faf..0874ae4 100644
--- a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mbx.c
+++ b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mbx.c
@@ -742,7 +742,7 @@ void hclge_mbx_handler(struct hclge_dev *hdev)
ret = hclge_get_link_info(vport, req);
if (ret)
dev_err(&hdev->pdev->dev,
- "PF fail(%d) to get link stat for VF\n",
+ "failed to inform link stat to VF, ret = %d\n",
ret);
break;
case HCLGE_MBX_QUEUE_RESET:
--
2.7.4