Re: [EXT] Re: [PATCH net-next v1] net: phy: tja11xx: add cable-test support

From: Oleksij Rempel
Date: Thu May 14 2020 - 13:27:13 EST


On Thu, May 14, 2020 at 06:01:52PM +0200, Andrew Lunn wrote:
> On Thu, May 14, 2020 at 03:47:16PM +0000, Christian Herber wrote:
> > Hi Andrew,
> >
> > > On Wed, May 13, 2020 at 03:39:00PM +0200, Andrew Lunn wrote:
> > >> On Thu, May 14, 2020 at 02:09:59PM +0200, Oleksij Rempel wrote:
> > >> ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER - the link partner is active.
> > >>
> > >> The TJA1102 is able to detect it if partner link is master.
> > >>
> > > master is not a cable diagnostics issue. This is a configuration
> > > issue.
> >
>
> > Master is very relevant for cable diagnostics, as a cable
> > measurement should not be done with an active link partner on the
> > other end (i.e. a PHY in master mode trying to train the link).
>
> > So if the measurement detects an active link partner disturbing the
> > measurement, it is important to report this to the user.
>
> So with 'normal' PHYs, we use autoneg to make the link go quiet. But
> you don't have autoneg.
>
> If there is no way to force the link quiet, then
> ETHTOOL_A_CABLE_RESULT_CODE_ACTIVE_PARTNER makes sense. But we need to
> keep the meaning generic. I don't want it to mean a T1 PHY with an
> active master peer. It should be usable for any reason the link cannot
> be made to go quiet.

It looks for me, like AT803X_CDT_STATUS_STAT_FAIL has the same reason as
ACTIVE PERTNER (Master) on TJA11xx.

What kind of meaning, naming would be generic?


--