[PATCH 00/10] power: supply: Charger-manager improvements

From: Jonathan Bakker
Date: Thu May 14 2020 - 19:05:08 EST


Charger-manager is a virtual driver for unifying chargers, fuel gauges,
extcon devices, and a thermal device into a battery management system.

Unfortunately, it has been broken since commit 830ae442202e ("extcon:
Remove the deprecated extcon functions") when the extcon internal API
was changed but some drivers were not updated. Additionally, it had
some race conditions and was unnecessarily complex.

A number of these patches come from a Tizen git tree(1); they have been
rebased and the commit messages cleaned up.

These changes have been tested on a couple of first-gen Galaxy S devices
based on s5pv210 with a modified max8998 driver so that a charger
regulator is exposed. In addition to the max8998, this hardware has
a max17040 fuel gauge, fsa9480 extcon, and a generic thermal resistor
for temperature sensing.

1) https://git.tizen.org/cgit/platform/kernel/linux-exynos/log/drivers/power/charger-manager.c?h=tizen_5.0

Jonathan Bakker (4):
power: supply: charger-manager: Always use POWER_SUPPLY_PROP_TEMP
power: supply: charger-manager: Update extcon functions
power: supply: charger-manager: Count cm-chargers property directly
dt-bindings: power: supply: Cleanup charger-manager bindings

Jonghwa Lee (6):
power: supply: charger-manager: Swap private uevent for
power_supply_changed
power: supply: charger-manager: Remove cm_notify_event function
power: supply: charger-manager: Correct usage of CHARGE_NOW/FULL
power: supply: charger-manager: Collect all power_supply_changed()
calls
power: supply: charger-manager: Make decisions focussed on battery
status
power: supply: charger-manager: Don't start charging in cable
nofitication

.../bindings/power/supply/charger-manager.txt | 30 +-
drivers/power/supply/charger-manager.c | 571 +++++-------------
include/linux/power/charger-manager.h | 41 +-
3 files changed, 175 insertions(+), 467 deletions(-)

--