Re: [PATCH v2 2/2] arm64: dts: rockchip: rk3399: fix pd_tcpc0 and pd_tcpc1 node position

From: Caesar Wang
Date: Mon May 18 2020 - 20:42:04 EST


Hi Heiko,

在 2020/5/19 上午6:29, Heiko Stübner 写道:
Hi Kever, Caesar,

could you double check where the type-c power-domains are located
in the power-tree, as Caesar did add them under pd_vio back in 2016.

Johan's patch is correct, the pd_tcpc0 and pd_tcpc1 are grouped by VDD_LOGIC.
I have a passed test for pd_vio without pd_tcpc*.


Thanks
Heiko

Am Dienstag, 28. April 2020, 22:30:03 CEST schrieb Johan Jonker:
The pd_tcpc0 and pd_tcpc1 nodes are currently a sub node of pd_vio.
In the rk3399 TRM figure of the 'Power Domain Partition' and in the
table of 'Power Domain and Voltage Domain Summary' these power domains
are positioned directly under VD_LOGIC, so fix that in 'rk3399.dtsi'.

Signed-off-by: Johan Jonker <jbx6244@xxxxxxxxx>


Reviewed-by: Caesar Wang <wxt@xxxxxxxxxxxxxx>

Thanks,

-Caesar

---
arch/arm64/boot/dts/rockchip/rk3399.dtsi | 20 ++++++++++----------
1 file changed, 10 insertions(+), 10 deletions(-)

diff --git a/arch/arm64/boot/dts/rockchip/rk3399.dtsi b/arch/arm64/boot/dts/rockchip/rk3399.dtsi
index 37279db53..a4dc1bf2e 100644
--- a/arch/arm64/boot/dts/rockchip/rk3399.dtsi
+++ b/arch/arm64/boot/dts/rockchip/rk3399.dtsi
@@ -1056,6 +1056,16 @@
clocks = <&cru HCLK_SDIO>;
pm_qos = <&qos_sdioaudio>;
};
+ pd_tcpc0@RK3399_PD_TCPD0 {
+ reg = <RK3399_PD_TCPD0>;
+ clocks = <&cru SCLK_UPHY0_TCPDCORE>,
+ <&cru SCLK_UPHY0_TCPDPHY_REF>;
+ };
+ pd_tcpc1@RK3399_PD_TCPD1 {
+ reg = <RK3399_PD_TCPD1>;
+ clocks = <&cru SCLK_UPHY1_TCPDCORE>,
+ <&cru SCLK_UPHY1_TCPDPHY_REF>;
+ };
pd_usb3@RK3399_PD_USB3 {
reg = <RK3399_PD_USB3>;
clocks = <&cru ACLK_USB3>;
@@ -1088,16 +1098,6 @@
pm_qos = <&qos_isp1_m0>,
<&qos_isp1_m1>;
};
- pd_tcpc0@RK3399_PD_TCPD0 {
- reg = <RK3399_PD_TCPD0>;
- clocks = <&cru SCLK_UPHY0_TCPDCORE>,
- <&cru SCLK_UPHY0_TCPDPHY_REF>;
- };
- pd_tcpc1@RK3399_PD_TCPD1 {
- reg = <RK3399_PD_TCPD1>;
- clocks = <&cru SCLK_UPHY1_TCPDCORE>,
- <&cru SCLK_UPHY1_TCPDPHY_REF>;
- };
pd_vo@RK3399_PD_VO {
reg = <RK3399_PD_VO>;
#address-cells = <1>;