[RESEND PATCH v14 07/11] pwm: sifive: Use 64-bit division macro
From: Guru Das Srinagesh
Date: Wed May 20 2020 - 18:56:42 EST
Since the PWM framework is switching struct pwm_args.period's datatype
to u64, prepare for this transition by using DIV64_U64_ROUND_CLOSEST to
handle a 64-bit divisor.
Signed-off-by: Guru Das Srinagesh <gurus@xxxxxxxxxxxxxx>
Acked-by: Palmer Dabbelt <palmerdabbelt@xxxxxxxxxx>
---
drivers/pwm/pwm-sifive.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/pwm/pwm-sifive.c b/drivers/pwm/pwm-sifive.c
index cc63f9b..62de0bb 100644
--- a/drivers/pwm/pwm-sifive.c
+++ b/drivers/pwm/pwm-sifive.c
@@ -181,7 +181,7 @@ static int pwm_sifive_apply(struct pwm_chip *chip, struct pwm_device *pwm,
* consecutively
*/
num = (u64)duty_cycle * (1U << PWM_SIFIVE_CMPWIDTH);
- frac = DIV_ROUND_CLOSEST_ULL(num, state->period);
+ frac = DIV64_U64_ROUND_CLOSEST(num, state->period);
/* The hardware cannot generate a 100% duty cycle */
frac = min(frac, (1U << PWM_SIFIVE_CMPWIDTH) - 1);
--
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum,
a Linux Foundation Collaborative Project