[PATCH] spi: tegra20-slink: Fix runtime PM imbalance on error

From: Dinghao Liu
Date: Thu May 21 2020 - 03:50:04 EST


pm_runtime_get_sync() increments the runtime PM usage counter even
when it returns an error code. Thus a pairing decrement is needed on
the error handling path to keep the counter balanced.

Signed-off-by: Dinghao Liu <dinghao.liu@xxxxxxxxxx>
---
drivers/spi/spi-tegra20-slink.c | 1 +
1 file changed, 1 insertion(+)

diff --git a/drivers/spi/spi-tegra20-slink.c b/drivers/spi/spi-tegra20-slink.c
index 7f4d932dade7..15361db00982 100644
--- a/drivers/spi/spi-tegra20-slink.c
+++ b/drivers/spi/spi-tegra20-slink.c
@@ -1118,6 +1118,7 @@ static int tegra_slink_probe(struct platform_device *pdev)
ret = pm_runtime_get_sync(&pdev->dev);
if (ret < 0) {
dev_err(&pdev->dev, "pm runtime get failed, e = %d\n", ret);
+ pm_runtime_put(&pdev->dev);
goto exit_pm_disable;
}
tspi->def_command_reg = SLINK_M_S;
--
2.17.1