Re: signal quality and cable diagnostic
From: Pavel Machek
Date: Sun May 24 2020 - 17:28:44 EST
On Tue 2020-05-12 15:04:18, Andrew Lunn wrote:
> > > As for getting / setting the threshold, perhaps ETHTOOL_MSG_LINKINFO_GET
> > > and ETHTOOL_MSG_LINKINFO_SET. Unless you expect more configurable
> > > parameters like this in which case we may want to consider adding new
> > > request type (e.g. link params or link management).
> >
> > Currently in my short term todo are:
> > - SQI
>
>
> > - PHY undervoltage
> > - PHY overtemerature
>
> Do you only have alarms? Or are current values available for voltage
> and temperature?
>
> Both of these would fit hwmon. It even has the option to set the alarm
> thresholds. The advantage of hwmon is that they are then just more
> sensors. You could even include the temperature sensor into a thermal zone to influence
> cooling. There are a couple of PHYs which already do hwmon, so there is code you can
> copy.
Yes, hwmon can do a lot of stuff. OTOH figuring out "what hwmon device corresponds to what
network device is going to be tricky, and Im not sure if we want utilities like mii-tool to
start using hwmon interfaces...
Best regards,
Pavel
--
(english) http://www.livejournal.com/~pavelmachek
(cesky, pictures) http://atrey.karlin.mff.cuni.cz/~pavel/picture/horses/blog.html