[PATCH v2 3/4] pwm: jz4740: Make PWM start with the active part
From: Paul Cercueil
Date: Mon May 25 2020 - 08:57:59 EST
The PWM in Ingenic SoCs starts in inactive state until the internal
timer reaches the duty value, then becomes active until the timer
reaches the period value. In theory, we should then use (period - duty)
as the real duty value, as a high duty value would otherwise result in
the PWM pin being inactive most of the time.
This is the reason why the duty value was inverted in the driver until
now, but it still had the problem that it would not start with the
active part.
To address this remaining issue, the common trick is to invert the
duty, and invert the polarity when the PWM is enabled.
Since the duty was already inverted, and we invert it again, we now
program the hardware for the requested duty, and simply invert the
polarity when the PWM is enabled.
Signed-off-by: Paul Cercueil <paul@xxxxxxxxxxxxxxx>
---
Notes:
v2: Add documentation about why we invert the polarity, and
improve commit message
drivers/pwm/pwm-jz4740.c | 25 ++++++++++++++++---------
1 file changed, 16 insertions(+), 9 deletions(-)
diff --git a/drivers/pwm/pwm-jz4740.c b/drivers/pwm/pwm-jz4740.c
index 4fe9d99ac9a9..fe06ca8ce30f 100644
--- a/drivers/pwm/pwm-jz4740.c
+++ b/drivers/pwm/pwm-jz4740.c
@@ -6,7 +6,6 @@
* Limitations:
* - The .apply callback doesn't complete the currently running period before
* reconfiguring the hardware.
- * - Each period starts with the inactive part.
*/
#include <linux/clk.h>
@@ -163,7 +162,7 @@ static int jz4740_pwm_apply(struct pwm_chip *chip, struct pwm_device *pwm,
/* Calculate duty value */
tmp = (unsigned long long)rate * state->duty_cycle;
do_div(tmp, NSEC_PER_SEC);
- duty = period - tmp;
+ duty = tmp;
if (duty >= period)
duty = period - 1;
@@ -189,18 +188,26 @@ static int jz4740_pwm_apply(struct pwm_chip *chip, struct pwm_device *pwm,
regmap_update_bits(jz4740->map, TCU_REG_TCSRc(pwm->hwpwm),
TCU_TCSR_PWM_SD, TCU_TCSR_PWM_SD);
- /* Set polarity */
- switch (state->polarity) {
- case PWM_POLARITY_NORMAL:
+ /*
+ * Set polarity.
+ *
+ * The PWM starts in inactive state until the internal timer reaches the
+ * duty value, then becomes active until the timer reaches the period
+ * value. In theory, we should then use (period - duty) as the real duty
+ * value, as a high duty value would otherwise result in the PWM pin
+ * being inactive most of the time.
+ *
+ * Here, we don't do that, and instead invert the polarity of the PWM
+ * when it is active. This trick makes the PWM start with its active
+ * state instead of its inactive state.
+ */
+ if ((state->polarity == PWM_POLARITY_NORMAL) ^ state->enabled)
regmap_update_bits(jz4740->map, TCU_REG_TCSRc(pwm->hwpwm),
TCU_TCSR_PWM_INITL_HIGH, 0);
- break;
- case PWM_POLARITY_INVERSED:
+ else
regmap_update_bits(jz4740->map, TCU_REG_TCSRc(pwm->hwpwm),
TCU_TCSR_PWM_INITL_HIGH,
TCU_TCSR_PWM_INITL_HIGH);
- break;
- }
if (state->enabled)
jz4740_pwm_enable(chip, pwm);
--
2.26.2