[PATCH v15 03/11] ir-rx51: Use 64-bit division macro
From: Guru Das Srinagesh
Date: Tue May 26 2020 - 13:35:34 EST
Since the PWM framework is switching struct pwm_state.period's datatype
to u64, prepare for this transition by using DIV_ROUND_CLOSEST_ULL to
handle a 64-bit dividend.
Signed-off-by: Guru Das Srinagesh <gurus@xxxxxxxxxxxxxx>
Acked-by: Sean Young <sean@xxxxxxxx>
---
drivers/media/rc/ir-rx51.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)
diff --git a/drivers/media/rc/ir-rx51.c b/drivers/media/rc/ir-rx51.c
index 8574eda..9a5dfd7 100644
--- a/drivers/media/rc/ir-rx51.c
+++ b/drivers/media/rc/ir-rx51.c
@@ -241,7 +241,8 @@ static int ir_rx51_probe(struct platform_device *dev)
}
/* Use default, in case userspace does not set the carrier */
- ir_rx51.freq = DIV_ROUND_CLOSEST(pwm_get_period(pwm), NSEC_PER_SEC);
+ ir_rx51.freq = DIV_ROUND_CLOSEST_ULL(pwm_get_period(pwm),
+ NSEC_PER_SEC);
pwm_put(pwm);
hrtimer_init(&ir_rx51.timer, CLOCK_MONOTONIC, HRTIMER_MODE_REL);
--
The Qualcomm Innovation Center, Inc. is a member of the Code Aurora Forum,