[v3,1/1] hwmon:(nct7904) Set default timeout
From: yuechao.zhao
Date: Wed May 27 2020 - 02:17:19 EST
From: Yuechao Zhao <yuechao.zhao@xxxxxxxxxxxxxxxx>
The timeout module parameter should not be used for setting the default
timeout. Because, if you set the timeout = 0, the default timeout will
be meaningless. And the timeout module parameter of 0 means "no timeout
module paraameter specified".
Signed-off-by: Yuechao Zhao <yuechao.zhao@xxxxxxxxxxxxxxxx>
---
Change in v3:
- replace 'static int timeout = WATCHDOG_TIMEOUT;' with 'static int timeout;'
- fixed typo
Change in v2:
- modify subject to 'hwmon:(nct7904) Set default timeout'
---
drivers/hwmon/nct7904.c | 8 ++++----
1 file changed, 4 insertions(+), 4 deletions(-)
diff --git a/drivers/hwmon/nct7904.c b/drivers/hwmon/nct7904.c
index 18c95be..b042569 100644
--- a/drivers/hwmon/nct7904.c
+++ b/drivers/hwmon/nct7904.c
@@ -111,14 +111,14 @@
#define MIN_TIMEOUT (1 * 60)
#define MAX_TIMEOUT (255 * 60)
-static int timeout = WATCHDOG_TIMEOUT;
+static int timeout;
module_param(timeout, int, 0);
MODULE_PARM_DESC(timeout, "Watchdog timeout in minutes. 1 <= timeout <= 255, default="
- __MODULE_STRING(WATCHODOG_TIMEOUT) ".");
+ __MODULE_STRING(WATCHDOG_TIMEOUT) ".");
static bool nowayout = WATCHDOG_NOWAYOUT;
module_param(nowayout, bool, 0);
-MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started once started (default="
+MODULE_PARM_DESC(nowayout, "Watchdog cannot be stopped once started (default="
__MODULE_STRING(WATCHDOG_NOWAYOUT) ")");
static const unsigned short normal_i2c[] = {
@@ -1147,7 +1147,7 @@ static int nct7904_probe(struct i2c_client *client,
data->wdt.ops = &nct7904_wdt_ops;
data->wdt.info = &nct7904_wdt_info;
- data->wdt.timeout = timeout * 60; /* in seconds */
+ data->wdt.timeout = WATCHDOG_TIMEOUT * 60; /* Set default timeout */
data->wdt.min_timeout = MIN_TIMEOUT;
data->wdt.max_timeout = MAX_TIMEOUT;
data->wdt.parent = &client->dev;
--
1.8.3.1