[PATCH 2/2] perf record: Fix --switch-output=time documentation
From: Ravi Bangoria
Date: Fri Jun 19 2020 - 09:34:35 EST
perf record man page uses word 'size' while describing
--switch-output=time option. Fix that.
Signed-off-by: Ravi Bangoria <ravi.bangoria@xxxxxxxxxxxxx>
---
tools/perf/Documentation/perf-record.txt | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/tools/perf/Documentation/perf-record.txt b/tools/perf/Documentation/perf-record.txt
index fa8a5fcd27ab..5256f5e12dde 100644
--- a/tools/perf/Documentation/perf-record.txt
+++ b/tools/perf/Documentation/perf-record.txt
@@ -540,7 +540,7 @@ based on 'mode' value:
"signal" - when receiving a SIGUSR2 (default value) or
<size> - when reaching the size threshold, size is expected to
be a number with appended unit character - B/K/M/G
- <time> - when reaching the time threshold, size is expected to
+ <time> - when reaching the time threshold, time is expected to
be a number with appended unit character - s/m/h/d
Note: the precision of the size threshold hugely depends
--
2.17.1