[PATCHv3 1/4] watchdog: use __watchdog_ping in startup

From: Tero Kristo
Date: Mon Jul 13 2020 - 09:20:00 EST


Current watchdog startup functionality does not respect the minimum hw
heartbeat setup and the last watchdog ping timeframe when watchdog is
already running and userspace process attaches to it. Fix this by using
the __watchdog_ping from the startup also. For this code path, we can
also let the __watchdog_ping handle the bookkeeping for the worker and
last keepalive times.

Signed-off-by: Tero Kristo <t-kristo@xxxxxx>
Reviewed-by: Guenter Roeck <linux@xxxxxxxxxxxx>
---
drivers/watchdog/watchdog_dev.c | 19 +++++++++++--------
1 file changed, 11 insertions(+), 8 deletions(-)

diff --git a/drivers/watchdog/watchdog_dev.c b/drivers/watchdog/watchdog_dev.c
index 7e4cd34a8c20..bc1cfa288553 100644
--- a/drivers/watchdog/watchdog_dev.c
+++ b/drivers/watchdog/watchdog_dev.c
@@ -275,15 +275,18 @@ static int watchdog_start(struct watchdog_device *wdd)
set_bit(_WDOG_KEEPALIVE, &wd_data->status);

started_at = ktime_get();
- if (watchdog_hw_running(wdd) && wdd->ops->ping)
- err = wdd->ops->ping(wdd);
- else
+ if (watchdog_hw_running(wdd) && wdd->ops->ping) {
+ err = __watchdog_ping(wdd);
+ if (err == 0)
+ set_bit(WDOG_ACTIVE, &wdd->status);
+ } else {
err = wdd->ops->start(wdd);
- if (err == 0) {
- set_bit(WDOG_ACTIVE, &wdd->status);
- wd_data->last_keepalive = started_at;
- wd_data->last_hw_keepalive = started_at;
- watchdog_update_worker(wdd);
+ if (err == 0) {
+ set_bit(WDOG_ACTIVE, &wdd->status);
+ wd_data->last_keepalive = started_at;
+ wd_data->last_hw_keepalive = started_at;
+ watchdog_update_worker(wdd);
+ }
}

return err;
--
2.17.1

--
Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki