Re: [PATCH v2 2/9] dt-bindings: battery: Add temperature properties

From: Rob Herring
Date: Mon Jul 13 2020 - 19:46:11 EST


On Sun, Jun 07, 2020 at 05:41:06PM +0300, Dmitry Osipenko wrote:
> Document generic battery temperature properties.
>
> Signed-off-by: Dmitry Osipenko <digetx@xxxxxxxxx>
> ---
> .../devicetree/bindings/power/supply/battery.txt | 10 ++++++++++
> 1 file changed, 10 insertions(+)

This is close to being converted to schema:

https://lore.kernel.org/linux-pm/20200707212914.31540-1-r-rivera-matos@xxxxxx/

> diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt
> index 5e29595edd74..e0c35eff9d3f 100644
> --- a/Documentation/devicetree/bindings/power/supply/battery.txt
> +++ b/Documentation/devicetree/bindings/power/supply/battery.txt
> @@ -45,6 +45,16 @@ Optional Properties:
> and corresponding battery internal resistance percent, which is used to look
> up the resistance percent according to current temperature to get a accurate
> batterty internal resistance in different temperatures.
> + - temperature-ambient-min-alert-celsius: Alert when ambient temperature of a
> + battery is lower than threshold value.
> + - temperature-ambient-max-alert-celsius: Alert when ambient temperature of a
> + battery is higher than threshold value.
> + - temperature-min-alert-celsius: Alert when battery temperature is lower
> + than threshold value.
> + - temperature-max-alert-celsius: Alert when battery temperature is higher
> + than threshold value.
> + - temperature-min-celsius: minimum temperature at which battery can operate
> + - temperature-max-celsius: maximum temperature at which battery can operate

Perhaps 'temperature' is redundant since we have units.

Perhaps do <min max> properties given specifying only min or max is
probably not valid?

Rob