[PATCH 1/2] ASoC: fsl_asrc: make sure the input and output clocks are different

From: Arnaud Ferraris
Date: Thu Jul 16 2020 - 10:52:45 EST


The current clock selection algorithm might select the same clock for
both input and output. This can happen when, for instance, the output
sample rate is a multiple of the input rate.

This patch makes sure it always selects distinct input and output
clocks.

Signed-off-by: Arnaud Ferraris <arnaud.ferraris@xxxxxxxxxxxxx>
---
sound/soc/fsl/fsl_asrc.c | 3 ++-
1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/sound/soc/fsl/fsl_asrc.c b/sound/soc/fsl/fsl_asrc.c
index 02c81d2e34ad..bfd35b9c0781 100644
--- a/sound/soc/fsl/fsl_asrc.c
+++ b/sound/soc/fsl/fsl_asrc.c
@@ -622,7 +622,8 @@ static void fsl_asrc_select_clk(struct fsl_asrc_priv *asrc_priv,
clk_rate = clk_get_rate(asrc_priv->asrck_clk[clk_index]);
/* Only match a perfect clock source with no remainder */
if (clk_rate != 0 && (clk_rate / rate[j]) <= 1024 &&
- (clk_rate % rate[j]) == 0)
+ (clk_rate % rate[j]) == 0 &&
+ (j == 0 || i != select_clk[j-1]))
break;
}

--
2.27.0