Re: [PATCH v4 4/4] dt-bindings: timer: Add CLINT bindings

From: Sean Anderson
Date: Tue Jul 21 2020 - 08:18:04 EST


On 7/20/20 9:15 PM, Atish Patra wrote:
> On Fri, Jul 17, 2020 at 12:52 AM Anup Patel <anup.patel@xxxxxxx> wrote:
>>
>> We add DT bindings documentation for CLINT device.
>>
>> Signed-off-by: Anup Patel <anup.patel@xxxxxxx>
>> Reviewed-by: Palmer Dabbelt <palmerdabbelt@xxxxxxxxxx>
>> Tested-by: Emil Renner Berhing <kernel@xxxxxxxx>
>> ---
>> .../bindings/timer/sifive,clint.yaml | 58 +++++++++++++++++++
>> 1 file changed, 58 insertions(+)
>> create mode 100644 Documentation/devicetree/bindings/timer/sifive,clint.yaml
>>
>> diff --git a/Documentation/devicetree/bindings/timer/sifive,clint.yaml b/Documentation/devicetree/bindings/timer/sifive,clint.yaml
>> new file mode 100644
>> index 000000000000..8ad115611860
>> --- /dev/null
>> +++ b/Documentation/devicetree/bindings/timer/sifive,clint.yaml
>> @@ -0,0 +1,58 @@
>> +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
>> +%YAML 1.2
>> +---
>> +$id: http://devicetree.org/schemas/timer/sifive,clint.yaml#
>> +$schema: http://devicetree.org/meta-schemas/core.yaml#
>> +
>> +title: SiFive Core Local Interruptor
>> +
>> +maintainers:
>> + - Palmer Dabbelt <palmer@xxxxxxxxxxx>
>> + - Anup Patel <anup.patel@xxxxxxx>
>> +
>> +description:
>> + SiFive (and other RISC-V) SOCs include an implementation of the SiFive
>> + Core Local Interruptor (CLINT) for M-mode timer and M-mode inter-processor
>> + interrupts. It directly connects to the timer and inter-processor interrupt
>> + lines of various HARTs (or CPUs) so RISC-V per-HART (or per-CPU) local
>> + interrupt controller is the parent interrupt controller for CLINT device.
>> + The clock frequency of CLINT is specified via "timebase-frequency" DT
>> + property of "/cpus" DT node. The "timebase-frequency" DT property is
>> + described in Documentation/devicetree/bindings/riscv/cpus.yaml
>> +
>> +properties:
>> + compatible:
>> + items:
>> + - const: sifive,clint0
>> + - const: sifive,fu540-c000-clint
>> +
>> + description:
>> + Should be "sifive,<chip>-clint" and "sifive,clint<version>".
>> + Supported compatible strings are -
>> + "sifive,fu540-c000-clint" for the SiFive CLINT v0 as integrated
>> + onto the SiFive FU540 chip, and "sifive,clint0" for the SiFive
>> + CLINT v0 IP block with no chip integration tweaks.
>> + Please refer to sifive-blocks-ip-versioning.txt for details
>> +
>
> As the DT binding suggests that the clint device should be named as "sifive,**",
> I think we should change the DT property in kendryte dts as well.

The kendryte device is based on Rocket Chip, not any SiFive IP/device.
If anything, the general binding should be "chipsalliance,clint" and the
specific bindings should be "sifive,clint" and "kendryte,clint" (or
"canaan,clint").

--Sean