Re: [PATCH v5 4/5] iio:temperature:mlx90632: Adding extended calibration option
From: Andy Shevchenko
Date: Thu Aug 13 2020 - 07:06:33 EST
On Thu, Aug 13, 2020 at 10:53 AM Crt Mori <cmo@xxxxxxxxxxx> wrote:
>
> For some time the market wants medical grade accuracy in medical range,
> while still retaining the declared accuracy outside of the medical range
> within the same sensor. That is why we created extended calibration
> which is automatically switched to when object temperature is too high.
>
> This patch also introduces the object_ambient_temperature variable which
> is needed for more accurate calculation of the object infra-red
> footprint as sensor's ambient temperature might be totally different
> than what the ambient temperature is at object and that is why we can
> have some more errors which can be eliminated. Currently this temperature
> is fixed at 25, but the interface to adjust it by user (with external
> sensor or just IR measurement of the other object which acts as ambient),
> will be introduced in another commit.
FWIW,
Reviewed-by: Andy Shevchenko <andy.shevchenko@xxxxxxxxx>
> Signed-off-by: Crt Mori <cmo@xxxxxxxxxxx>
> ---
> drivers/iio/temperature/mlx90632.c | 224 ++++++++++++++++++++++++++++-
> 1 file changed, 222 insertions(+), 2 deletions(-)
>
> diff --git a/drivers/iio/temperature/mlx90632.c b/drivers/iio/temperature/mlx90632.c
> index d87c792b7e72..9fa8c078c037 100644
> --- a/drivers/iio/temperature/mlx90632.c
> +++ b/drivers/iio/temperature/mlx90632.c
> @@ -11,6 +11,7 @@
> #include <linux/gpio/consumer.h>
> #include <linux/i2c.h>
> #include <linux/kernel.h>
> +#include <linux/limits.h>
> #include <linux/module.h>
> #include <linux/math64.h>
> #include <linux/of.h>
> @@ -58,6 +59,8 @@
> /* Control register address - volatile */
> #define MLX90632_REG_CONTROL 0x3001 /* Control Register address */
> #define MLX90632_CFG_PWR_MASK GENMASK(2, 1) /* PowerMode Mask */
> +#define MLX90632_CFG_MTYP_MASK GENMASK(8, 4) /* Meas select Mask */
> +
> /* PowerModes statuses */
> #define MLX90632_PWR_STATUS(ctrl_val) (ctrl_val << 1)
> #define MLX90632_PWR_STATUS_HALT MLX90632_PWR_STATUS(0) /* hold */
> @@ -65,6 +68,18 @@
> #define MLX90632_PWR_STATUS_STEP MLX90632_PWR_STATUS(2) /* step */
> #define MLX90632_PWR_STATUS_CONTINUOUS MLX90632_PWR_STATUS(3) /* continuous*/
>
> +/* Measurement types */
> +#define MLX90632_MTYP_MEDICAL 0
> +#define MLX90632_MTYP_EXTENDED 17
> +
> +/* Measurement type select*/
> +#define MLX90632_MTYP_STATUS(ctrl_val) (ctrl_val << 4)
> +#define MLX90632_MTYP_STATUS_MEDICAL MLX90632_MTYP_STATUS(MLX90632_MTYP_MEDICAL)
> +#define MLX90632_MTYP_STATUS_EXTENDED MLX90632_MTYP_STATUS(MLX90632_MTYP_EXTENDED)
> +
> +/* I2C command register - volatile */
> +#define MLX90632_REG_I2C_CMD 0x3005 /* I2C command Register address */
> +
> /* Device status register - volatile */
> #define MLX90632_REG_STATUS 0x3fff /* Device status register */
> #define MLX90632_STAT_BUSY BIT(10) /* Device busy indicator */
> @@ -78,9 +93,21 @@
> #define MLX90632_RAM_2(meas_num) (MLX90632_ADDR_RAM + 3 * meas_num + 1)
> #define MLX90632_RAM_3(meas_num) (MLX90632_ADDR_RAM + 3 * meas_num + 2)
>
> +/* Name important RAM_MEAS channels */
> +#define MLX90632_RAM_DSP5_EXTENDED_AMBIENT_1 MLX90632_RAM_3(17)
> +#define MLX90632_RAM_DSP5_EXTENDED_AMBIENT_2 MLX90632_RAM_3(18)
> +#define MLX90632_RAM_DSP5_EXTENDED_OBJECT_1 MLX90632_RAM_1(17)
> +#define MLX90632_RAM_DSP5_EXTENDED_OBJECT_2 MLX90632_RAM_2(17)
> +#define MLX90632_RAM_DSP5_EXTENDED_OBJECT_3 MLX90632_RAM_1(18)
> +#define MLX90632_RAM_DSP5_EXTENDED_OBJECT_4 MLX90632_RAM_2(18)
> +#define MLX90632_RAM_DSP5_EXTENDED_OBJECT_5 MLX90632_RAM_1(19)
> +#define MLX90632_RAM_DSP5_EXTENDED_OBJECT_6 MLX90632_RAM_2(19)
> +
> /* Magic constants */
> #define MLX90632_ID_MEDICAL 0x0105 /* EEPROM DSPv5 Medical device id */
> #define MLX90632_ID_CONSUMER 0x0205 /* EEPROM DSPv5 Consumer device id */
> +#define MLX90632_ID_EXTENDED 0x0505 /* EEPROM DSPv5 Extended range device id */
> +#define MLX90632_ID_MASK GENMASK(14, 0) /* DSP version and device ID in EE_VERSION */
> #define MLX90632_DSP_VERSION 5 /* DSP version */
> #define MLX90632_DSP_MASK GENMASK(7, 0) /* DSP version in EE_VERSION */
> #define MLX90632_RESET_CMD 0x0006 /* Reset sensor (address or global) */
> @@ -88,6 +115,7 @@
> #define MLX90632_REF_3 12LL /**< ResCtrlRef value of Channel 3 */
> #define MLX90632_MAX_MEAS_NUM 31 /**< Maximum measurements in list */
> #define MLX90632_SLEEP_DELAY_MS 3000 /**< Autosleep delay */
> +#define MLX90632_EXTENDED_LIMIT 27000 /* Extended mode raw value limit */
>
> /**
> * struct mlx90632_data - private data for the MLX90632 device
> @@ -95,16 +123,23 @@
> * @lock: Internal mutex for multiple reads for single measurement
> * @regmap: Regmap of the device
> * @emissivity: Object emissivity from 0 to 1000 where 1000 = 1.
> + * @mtyp: Measurement type physical sensor configuration for extended range
> + * calculations
> + * @object_ambient_temperature: Ambient temperature at object (might differ of
> + * the ambient temperature of sensor.
> */
> struct mlx90632_data {
> struct i2c_client *client;
> struct mutex lock;
> struct regmap *regmap;
> u16 emissivity;
> + u8 mtyp;
> + u32 object_ambient_temperature;
> };
>
> static const struct regmap_range mlx90632_volatile_reg_range[] = {
> regmap_reg_range(MLX90632_REG_I2C_ADDR, MLX90632_REG_CONTROL),
> + regmap_reg_range(MLX90632_REG_I2C_CMD, MLX90632_REG_I2C_CMD),
> regmap_reg_range(MLX90632_REG_STATUS, MLX90632_REG_STATUS),
> regmap_reg_range(MLX90632_RAM_1(0),
> MLX90632_RAM_3(MLX90632_MAX_MEAS_NUM)),
> @@ -120,6 +155,7 @@ static const struct regmap_range mlx90632_read_reg_range[] = {
> regmap_reg_range(MLX90632_EE_CTRL, MLX90632_EE_I2C_ADDR),
> regmap_reg_range(MLX90632_EE_Ha, MLX90632_EE_Hb),
> regmap_reg_range(MLX90632_REG_I2C_ADDR, MLX90632_REG_CONTROL),
> + regmap_reg_range(MLX90632_REG_I2C_CMD, MLX90632_REG_I2C_CMD),
> regmap_reg_range(MLX90632_REG_STATUS, MLX90632_REG_STATUS),
> regmap_reg_range(MLX90632_RAM_1(0),
> MLX90632_RAM_3(MLX90632_MAX_MEAS_NUM)),
> @@ -204,6 +240,26 @@ static int mlx90632_perform_measurement(struct mlx90632_data *data)
> return (reg_status & MLX90632_STAT_CYCLE_POS) >> 2;
> }
>
> +static int mlx90632_set_meas_type(struct regmap *regmap, u8 type)
> +{
> + int ret;
> +
> + if ((type != MLX90632_MTYP_MEDICAL) && (type != MLX90632_MTYP_EXTENDED))
> + return -EINVAL;
> +
> + ret = regmap_write(regmap, MLX90632_REG_I2C_CMD, MLX90632_RESET_CMD);
> + if (ret < 0)
> + return ret;
> +
> + ret = regmap_write_bits(regmap, MLX90632_REG_CONTROL,
> + (MLX90632_CFG_MTYP_MASK | MLX90632_CFG_PWR_MASK),
> + (MLX90632_MTYP_STATUS(type) | MLX90632_PWR_STATUS_HALT));
> + if (ret < 0)
> + return ret;
> +
> + return mlx90632_pwr_continuous(regmap);
> +}
> +
> static int mlx90632_channel_new_select(int perform_ret, uint8_t *channel_new,
> uint8_t *channel_old)
> {
> @@ -305,6 +361,104 @@ static int mlx90632_read_all_channel(struct mlx90632_data *data,
> return ret;
> }
>
> +static int mlx90632_read_ambient_raw_extended(struct regmap *regmap,
> + s16 *ambient_new_raw, s16 *ambient_old_raw)
> +{
> + unsigned int read_tmp;
> + int ret;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_AMBIENT_1, &read_tmp);
> + if (ret < 0)
> + return ret;
> + *ambient_new_raw = (s16)read_tmp;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_AMBIENT_2, &read_tmp);
> + if (ret < 0)
> + return ret;
> + *ambient_old_raw = (s16)read_tmp;
> +
> + return 0;
> +}
> +
> +static int mlx90632_read_object_raw_extended(struct regmap *regmap, s16 *object_new_raw)
> +{
> + unsigned int read_tmp;
> + s32 read;
> + int ret;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_OBJECT_1, &read_tmp);
> + if (ret < 0)
> + return ret;
> + read = (s16)read_tmp;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_OBJECT_2, &read_tmp);
> + if (ret < 0)
> + return ret;
> + read = read - (s16)read_tmp;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_OBJECT_3, &read_tmp);
> + if (ret < 0)
> + return ret;
> + read = read - (s16)read_tmp;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_OBJECT_4, &read_tmp);
> + if (ret < 0)
> + return ret;
> + read = (read + (s16)read_tmp) / 2;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_OBJECT_5, &read_tmp);
> + if (ret < 0)
> + return ret;
> + read = read + (s16)read_tmp;
> +
> + ret = regmap_read(regmap, MLX90632_RAM_DSP5_EXTENDED_OBJECT_6, &read_tmp);
> + if (ret < 0)
> + return ret;
> + read = read + (s16)read_tmp;
> +
> + if (read > S16_MAX || read < S16_MIN)
> + return -ERANGE;
> +
> + *object_new_raw = read;
> +
> + return 0;
> +}
> +
> +static int mlx90632_read_all_channel_extended(struct mlx90632_data *data, s16 *object_new_raw,
> + s16 *ambient_new_raw, s16 *ambient_old_raw)
> +{
> + int tries = 4;
> + int ret;
> +
> + mutex_lock(&data->lock);
> + ret = mlx90632_set_meas_type(data->regmap, MLX90632_MTYP_EXTENDED);
> + if (ret < 0)
> + goto read_unlock;
> +
> + do {
> + ret = mlx90632_perform_measurement(data);
> + if (ret < 0)
> + goto read_unlock;
> + } while ((ret != 19) && tries--);
> +
> + if (tries < 0) {
> + ret = -ETIMEDOUT;
> + goto read_unlock;
> + }
> +
> + ret = mlx90632_read_object_raw_extended(data->regmap, object_new_raw);
> + if (ret < 0)
> + goto read_unlock;
> +
> + ret = mlx90632_read_ambient_raw_extended(data->regmap, ambient_new_raw, ambient_old_raw);
> +
> +read_unlock:
> + (void) mlx90632_set_meas_type(data->regmap, MLX90632_MTYP_MEDICAL);
> +
> + mutex_unlock(&data->lock);
> + return ret;
> +}
> +
> static int mlx90632_read_ee_register(struct regmap *regmap, u16 reg_lsb,
> s32 *reg_value)
> {
> @@ -359,9 +513,23 @@ static s64 mlx90632_preprocess_temp_obj(s16 object_new_raw, s16 object_old_raw,
> return div64_s64((tmp << 19ULL), 1000LL);
> }
>
> +static s64 mlx90632_preprocess_temp_obj_extended(s16 object_new_raw, s16 ambient_new_raw,
> + s16 ambient_old_raw, s16 Ka)
> +{
> + s64 VR_IR, kKa, tmp;
> +
> + kKa = ((s64)Ka * 1000LL) >> 10ULL;
> + VR_IR = (s64)ambient_old_raw * 1000000LL +
> + kKa * div64_s64((s64)ambient_new_raw * 1000LL,
> + MLX90632_REF_3);
> + tmp = div64_s64(
> + div64_s64((s64) object_new_raw * 1000000000000LL, MLX90632_REF_12),
> + VR_IR);
> + return div64_s64(tmp << 19ULL, 1000LL);
> +}
> +
> static s32 mlx90632_calc_temp_ambient(s16 ambient_new_raw, s16 ambient_old_raw,
> - s32 P_T, s32 P_R, s32 P_G, s32 P_O,
> - s16 Gb)
> + s32 P_T, s32 P_R, s32 P_G, s32 P_O, s16 Gb)
> {
> s64 Asub, Bsub, Ablock, Bblock, Cblock, AMB, sum;
>
> @@ -433,6 +601,31 @@ static s32 mlx90632_calc_temp_object(s64 object, s64 ambient, s32 Ea, s32 Eb,
> return temp;
> }
>
> +static s32 mlx90632_calc_temp_object_extended(s64 object, s64 ambient, s64 reflected,
> + s32 Ea, s32 Eb, s32 Fa, s32 Fb, s32 Ga,
> + s16 Ha, s16 Hb, u16 tmp_emi)
> +{
> + s64 kTA, kTA0, TAdut, TAdut4, Tr4, TaTr4;
> + s64 temp = 25000;
> + s8 i;
> +
> + kTA = (Ea * 1000LL) >> 16LL;
> + kTA0 = (Eb * 1000LL) >> 8LL;
> + TAdut = div64_s64((ambient - kTA0) * 1000000LL, kTA) + 25 * 1000000LL;
> + Tr4 = mlx90632_calc_ta4(reflected, 10);
> + TAdut4 = mlx90632_calc_ta4(TAdut, 10000LL);
> + TaTr4 = Tr4 - div64_s64(Tr4 - TAdut4, tmp_emi) * 1000;
> +
> + /* Iterations of calculation as described in datasheet */
> + for (i = 0; i < 5; ++i) {
> + temp = mlx90632_calc_temp_object_iteration(temp, object, TAdut, TaTr4,
> + Fa / 2, Fb, Ga, Ha, Hb,
> + tmp_emi);
> + }
> +
> + return temp;
> +}
> +
> static int mlx90632_calc_object_dsp105(struct mlx90632_data *data, int *val)
> {
> s32 ret;
> @@ -480,6 +673,26 @@ static int mlx90632_calc_object_dsp105(struct mlx90632_data *data, int *val)
> if (ret < 0)
> return ret;
>
> + if (object_new_raw > MLX90632_EXTENDED_LIMIT &&
> + data->mtyp == MLX90632_MTYP_EXTENDED) {
> + ret = mlx90632_read_all_channel_extended(data, &object_new_raw,
> + &ambient_new_raw, &ambient_old_raw);
> + if (ret < 0)
> + return ret;
> +
> + /* Use extended mode calculations */
> + ambient = mlx90632_preprocess_temp_amb(ambient_new_raw,
> + ambient_old_raw, Gb);
> + object = mlx90632_preprocess_temp_obj_extended(object_new_raw,
> + ambient_new_raw,
> + ambient_old_raw, Ka);
> + *val = mlx90632_calc_temp_object_extended(object, ambient,
> + data->object_ambient_temperature,
> + Ea, Eb, Fa, Fb, Ga,
> + Ha, Hb, data->emissivity);
> + return 0;
> + }
> +
> ambient = mlx90632_preprocess_temp_amb(ambient_new_raw,
> ambient_old_raw, Gb);
> object = mlx90632_preprocess_temp_obj(object_new_raw,
> @@ -653,6 +866,7 @@ static int mlx90632_probe(struct i2c_client *client,
> i2c_set_clientdata(client, indio_dev);
> mlx90632->client = client;
> mlx90632->regmap = regmap;
> + mlx90632->mtyp = MLX90632_MTYP_MEDICAL;
>
> mutex_init(&mlx90632->lock);
> indio_dev->name = id->name;
> @@ -672,12 +886,17 @@ static int mlx90632_probe(struct i2c_client *client,
> dev_err(&client->dev, "read of version failed: %d\n", ret);
> return ret;
> }
> + read = read & MLX90632_ID_MASK;
> if (read == MLX90632_ID_MEDICAL) {
> dev_dbg(&client->dev,
> "Detected Medical EEPROM calibration %x\n", read);
> } else if (read == MLX90632_ID_CONSUMER) {
> dev_dbg(&client->dev,
> "Detected Consumer EEPROM calibration %x\n", read);
> + } else if (read == MLX90632_ID_EXTENDED) {
> + dev_dbg(&client->dev,
> + "Detected Extended range EEPROM calibration %x\n", read);
> + mlx90632->mtyp = MLX90632_MTYP_EXTENDED;
> } else if ((read & MLX90632_DSP_MASK) == MLX90632_DSP_VERSION) {
> dev_dbg(&client->dev,
> "Detected Unknown EEPROM calibration %x\n", read);
> @@ -689,6 +908,7 @@ static int mlx90632_probe(struct i2c_client *client,
> }
>
> mlx90632->emissivity = 1000;
> + mlx90632->object_ambient_temperature = 25000; /* 25 degrees milliCelsius */
>
> pm_runtime_disable(&client->dev);
> ret = pm_runtime_set_active(&client->dev);
> --
> 2.25.1
>
--
With Best Regards,
Andy Shevchenko