[PATCH v2 1/6] dt-bindings: timers: sp-804: Convert to json-schema

From: Andre Przywara
Date: Fri Aug 28 2020 - 10:20:35 EST


This converts the DT binding documentation for the ARM SP-804 timer IP
over to json-schema.
Most properties are just carried over, the clocks property requirement
(either one or three clocks) is now formalised and enforced.
As the former binding didn't specify clock-names, and there is no
common name used by the existing DTs, I refrained from adding them in
detail (just allowing the property).
The requirement for the APB clock is enforced by the primecell binding
already.

Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx>
---
.../devicetree/bindings/timer/arm,sp804.txt | 29 ------
.../devicetree/bindings/timer/arm,sp804.yaml | 93 +++++++++++++++++++
2 files changed, 93 insertions(+), 29 deletions(-)
delete mode 100644 Documentation/devicetree/bindings/timer/arm,sp804.txt
create mode 100644 Documentation/devicetree/bindings/timer/arm,sp804.yaml

diff --git a/Documentation/devicetree/bindings/timer/arm,sp804.txt b/Documentation/devicetree/bindings/timer/arm,sp804.txt
deleted file mode 100644
index 5cd8eee74af1..000000000000
--- a/Documentation/devicetree/bindings/timer/arm,sp804.txt
+++ /dev/null
@@ -1,29 +0,0 @@
-ARM sp804 Dual Timers
----------------------------------------
-
-Required properties:
-- compatible: Should be "arm,sp804" & "arm,primecell"
-- interrupts: Should contain the list of Dual Timer interrupts. This is the
- interrupt for timer 1 and timer 2. In the case of a single entry, it is
- the combined interrupt or if "arm,sp804-has-irq" is present that
- specifies which timer interrupt is connected.
-- reg: Should contain location and length for dual timer register.
-- clocks: clocks driving the dual timer hardware. This list should be 1 or 3
- clocks. With 3 clocks, the order is timer0 clock, timer1 clock,
- apb_pclk. A single clock can also be specified if the same clock is
- used for all clock inputs.
-
-Optional properties:
-- arm,sp804-has-irq = <#>: In the case of only 1 timer irq line connected, this
- specifies if the irq connection is for timer 1 or timer 2. A value of 1
- or 2 should be used.
-
-Example:
-
- timer0: timer@fc800000 {
- compatible = "arm,sp804", "arm,primecell";
- reg = <0xfc800000 0x1000>;
- interrupts = <0 0 4>, <0 1 4>;
- clocks = <&timclk1 &timclk2 &pclk>;
- clock-names = "timer1", "timer2", "apb_pclk";
- };
diff --git a/Documentation/devicetree/bindings/timer/arm,sp804.yaml b/Documentation/devicetree/bindings/timer/arm,sp804.yaml
new file mode 100644
index 000000000000..609972379637
--- /dev/null
+++ b/Documentation/devicetree/bindings/timer/arm,sp804.yaml
@@ -0,0 +1,93 @@
+# SPDX-License-Identifier: GPL-2.0
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/timer/arm,sp804.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: ARM sp804 Dual Timers
+
+maintainers:
+ - Haojian Zhuang <haojian.zhuang@xxxxxxxxxx>
+
+description: |+
+ The Arm SP804 IP implements two independent timers, configurable for
+ 16 or 32 bit operation and capable of running in one-shot, periodic, or
+ free-running mode. The input clock is shared, but can be gated and prescaled
+ independently for each timer.
+
+allOf:
+ - $ref: /schemas/arm/primecell.yaml#
+
+# Need a custom select here or 'arm,primecell' will match on lots of nodes
+select:
+ properties:
+ compatible:
+ contains:
+ const: arm,sp804
+ required:
+ - compatible
+
+properties:
+ compatible:
+ items:
+ - const: arm,sp804
+ - const: arm,primecell
+
+ interrupts:
+ description: |
+ If two interrupts are listed, those are the interrupts for timer
+ 1 and 2, respectively. If there is only a single interrupt, it is
+ either a combined interrupt or the sole interrupt of one timer, as
+ specified by the "arm,sp804-has-irq" property.
+ minItems: 1
+ maxItems: 2
+
+ reg:
+ description: The physical base address of the SP804 IP.
+ maxItems: 1
+
+ clocks:
+ description: |
+ Clocks driving the dual timer hardware. This list should
+ be 1 or 3 clocks. With 3 clocks, the order is timer0 clock, timer1
+ clock, apb_pclk. A single clock can also be specified if the same
+ clock is used for all clock inputs.
+ oneOf:
+ - items:
+ - description: clock for timer 1
+ - description: clock for timer 2
+ - description: bus clock
+ - items:
+ - description: unified clock for both timers and the bus
+
+ clock-names: true
+ # The original binding did not specify any clock names, and there is no
+ # consistent naming used in the existing DTs. The primecell binding
+ # requires the "apb_pclk" name, so we need this property.
+ # Use "timer0clk", "timer1clk", "apb_pclk" for new DTs.
+
+ arm,sp804-has-irq:
+ description: If only one interrupt line is connected to the interrupt
+ controller, this property specifies which timer is connected to this
+ line.
+ $ref: /schemas/types.yaml#/definitions/uint32
+ minimum: 1
+ maximum: 2
+
+required:
+ - compatible
+ - interrupts
+ - reg
+ - clocks
+
+additionalProperties: false
+
+examples:
+ - |
+ timer0: timer@fc800000 {
+ compatible = "arm,sp804", "arm,primecell";
+ reg = <0xfc800000 0x1000>;
+ interrupts = <0 0 4>, <0 1 4>;
+ clocks = <&timclk1>, <&timclk2>, <&pclk>;
+ clock-names = "timer1", "timer2", "apb_pclk";
+ };
--
2.17.1