[PATCH v3 2/6] ARM: dts: nspire: Fix SP804 users

From: Andre Przywara
Date: Mon Sep 07 2020 - 08:24:19 EST


Even though the SP804 binding allows to specify only one clock, the
primecell driver requires a named clock to activate the bus clock.

Specify the one clock three times and provide some clock-names, to
make the DT match the SP804 and primecell binding.

Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx>
---
arch/arm/boot/dts/nspire.dtsi | 12 ++++++++----
1 file changed, 8 insertions(+), 4 deletions(-)

diff --git a/arch/arm/boot/dts/nspire.dtsi b/arch/arm/boot/dts/nspire.dtsi
index d9a0fd7524dc..90e033d9141f 100644
--- a/arch/arm/boot/dts/nspire.dtsi
+++ b/arch/arm/boot/dts/nspire.dtsi
@@ -145,15 +145,19 @@

timer0: timer@900C0000 {
reg = <0x900C0000 0x1000>;
-
- clocks = <&timer_clk>;
+ clocks = <&timer_clk>, <&timer_clk>,
+ <&timer_clk>;
+ clock-names = "timer0clk", "timer1clk",
+ "apb_pclk";
};

timer1: timer@900D0000 {
reg = <0x900D0000 0x1000>;
interrupts = <19>;
-
- clocks = <&timer_clk>;
+ clocks = <&timer_clk>, <&timer_clk>,
+ <&timer_clk>;
+ clock-names = "timer0clk", "timer1clk",
+ "apb_pclk";
};

watchdog: watchdog@90060000 {
--
2.17.1