[v5 2/3] arm64: dts: mt8183: Configure CPU cooling

From: Michael Kao
Date: Tue Oct 13 2020 - 06:24:06 EST


From: Matthias Kaehlcke <mka@xxxxxxxxxxxx>

Add two passive trip points at 68°C and 80°C for the CPU temperature.

Signed-off-by: Matthias Kaehlcke <mka@xxxxxxxxxxxx>
Signed-off-by: Michael Kao <michael.kao@xxxxxxxxxxxx>
---
arch/arm64/boot/dts/mediatek/mt8183.dtsi | 56 ++++++++++++++++++++++++
1 file changed, 56 insertions(+)

diff --git a/arch/arm64/boot/dts/mediatek/mt8183.dtsi b/arch/arm64/boot/dts/mediatek/mt8183.dtsi
index 1cd093cf33f3..0614f18a1ea2 100644
--- a/arch/arm64/boot/dts/mediatek/mt8183.dtsi
+++ b/arch/arm64/boot/dts/mediatek/mt8183.dtsi
@@ -10,6 +10,7 @@
#include <dt-bindings/interrupt-controller/irq.h>
#include <dt-bindings/reset-controller/mt8183-resets.h>
#include <dt-bindings/phy/phy.h>
+#include <dt-bindings/thermal/thermal.h>
#include "mt8183-pinfunc.h"

/ {
@@ -450,6 +451,61 @@
polling-delay = <500>;
thermal-sensors = <&thermal 0>;
sustainable-power = <5000>;
+
+ trips {
+ threshold: trip-point@0 {
+ temperature = <68000>;
+ hysteresis = <2000>;
+ type = "passive";
+ };
+
+ target: trip-point@1 {
+ temperature = <80000>;
+ hysteresis = <2000>;
+ type = "passive";
+ };
+
+ cpu_crit: cpu-crit {
+ temperature = <115000>;
+ hysteresis = <2000>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ map0 {
+ trip = <&target>;
+ cooling-device = <&cpu0
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>,
+ <&cpu1
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>,
+ <&cpu2
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>,
+ <&cpu3
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>;
+ contribution = <3072>;
+ };
+ map1 {
+ trip = <&target>;
+ cooling-device = <&cpu4
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>,
+ <&cpu5
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>,
+ <&cpu6
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>,
+ <&cpu7
+ THERMAL_NO_LIMIT
+ THERMAL_NO_LIMIT>;
+ contribution = <1024>;
+ };
+ };
};

/* The tzts1 ~ tzts6 don't need to polling */
--
2.18.0