Re: [RFC PATCH v3 9/9] ipu3-cio2: Add functionality allowing software_node connections to sensors on platforms designed for Windows

From: Sakari Ailus
Date: Sun Oct 25 2020 - 07:19:27 EST


Hi Daniel,

On Sat, Oct 24, 2020 at 09:28:07PM +0100, Dan Scally wrote:
...
> >> +int cio2_bridge_build(struct pci_dev *cio2)
> >> +{
> >> + struct fwnode_handle *fwnode;
> >> + int ret;
> >> +
> >> + pci_dev_get(cio2);
> > Could you check that this isn't used by more than one user? The current
> > implementation assumes that. I'm not sure if there could be more instances
> > of CIO2 but if there were, that'd be an issue currently.
>
> I can check; can't think of anything better than just failing out if it
> turns out to be in use already though - any ideas or is that appropriate?

A negative error code would be appropriate, e.g. -EBUSY.

--
Regards,