Re: [PATCH 20/33] docs: ABI: testing: make the files compatible with ReST output
From: Jonathan Cameron
Date: Thu Oct 29 2020 - 10:49:34 EST
On Wed, 28 Oct 2020 15:23:18 +0100
Mauro Carvalho Chehab <mchehab+huawei@xxxxxxxxxx> wrote:
> From: Mauro Carvalho Chehab <mchehab+samsung@xxxxxxxxxx>
>
> Some files over there won't parse well by Sphinx.
>
> Fix them.
>
> Signed-off-by: Mauro Carvalho Chehab <mchehab+samsung@xxxxxxxxxx>
> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@xxxxxxxxxx>
Query below... I'm going to guess a rebase issue?
Other than that
Acked-by: Jonathan Cameron <Jonathan.Cameron@xxxxxxxxxx> # for IIO
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32 b/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
> index b7259234ad70..a10a4de3e5fe 100644
> --- a/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
> +++ b/Documentation/ABI/testing/sysfs-bus-iio-timer-stm32
> @@ -3,67 +3,85 @@ KernelVersion: 4.11
> Contact: benjamin.gaignard@xxxxxx
> Description:
> Reading returns the list possible master modes which are:
> - - "reset" : The UG bit from the TIMx_EGR register is
> +
> +
> + - "reset"
> + The UG bit from the TIMx_EGR register is
> used as trigger output (TRGO).
> - - "enable" : The Counter Enable signal CNT_EN is used
> + - "enable"
> + The Counter Enable signal CNT_EN is used
> as trigger output.
> - - "update" : The update event is selected as trigger output.
> + - "update"
> + The update event is selected as trigger output.
> For instance a master timer can then be used
> as a prescaler for a slave timer.
> - - "compare_pulse" : The trigger output send a positive pulse
> - when the CC1IF flag is to be set.
> - - "OC1REF" : OC1REF signal is used as trigger output.
> - - "OC2REF" : OC2REF signal is used as trigger output.
> - - "OC3REF" : OC3REF signal is used as trigger output.
> - - "OC4REF" : OC4REF signal is used as trigger output.
> + - "compare_pulse"
> + The trigger output send a positive pulse
> + when the CC1IF flag is to be set.
> + - "OC1REF"
> + OC1REF signal is used as trigger output.
> + - "OC2REF"
> + OC2REF signal is used as trigger output.
> + - "OC3REF"
> + OC3REF signal is used as trigger output.
> + - "OC4REF"
> + OC4REF signal is used as trigger output.
> +
> Additional modes (on TRGO2 only):
> - - "OC5REF" : OC5REF signal is used as trigger output.
> - - "OC6REF" : OC6REF signal is used as trigger output.
> +
> + - "OC5REF"
> + OC5REF signal is used as trigger output.
> + - "OC6REF"
> + OC6REF signal is used as trigger output.
> - "compare_pulse_OC4REF":
> - OC4REF rising or falling edges generate pulses.
> + OC4REF rising or falling edges generate pulses.
> - "compare_pulse_OC6REF":
> - OC6REF rising or falling edges generate pulses.
> + OC6REF rising or falling edges generate pulses.
> - "compare_pulse_OC4REF_r_or_OC6REF_r":
> - OC4REF or OC6REF rising edges generate pulses.
> + OC4REF or OC6REF rising edges generate pulses.
> - "compare_pulse_OC4REF_r_or_OC6REF_f":
> - OC4REF rising or OC6REF falling edges generate pulses.
> + OC4REF rising or OC6REF falling edges generate
> + pulses.
> - "compare_pulse_OC5REF_r_or_OC6REF_r":
> - OC5REF or OC6REF rising edges generate pulses.
> + OC5REF or OC6REF rising edges generate pulses.
> - "compare_pulse_OC5REF_r_or_OC6REF_f":
> - OC5REF rising or OC6REF falling edges generate pulses.
> + OC5REF rising or OC6REF falling edges generate
> + pulses.
>
> - +-----------+ +-------------+ +---------+
> - | Prescaler +-> | Counter | +-> | Master | TRGO(2)
> - +-----------+ +--+--------+-+ |-> | Control +-->
> - | | || +---------+
> - +--v--------+-+ OCxREF || +---------+
> - | Chx compare +----------> | Output | ChX
> - +-----------+-+ | | Control +-->
> - . | | +---------+
> - . | | .
> - +-----------v-+ OC6REF | .
> - | Ch6 compare +---------+>
> - +-------------+
> + ::
>
> - Example with: "compare_pulse_OC4REF_r_or_OC6REF_r":
> + +-----------+ +-------------+ +---------+
> + | Prescaler +-> | Counter | +-> | Master | TRGO(2)
> + +-----------+ +--+--------+-+ |-> | Control +-->
> + | | || +---------+
> + +--v--------+-+ OCxREF || +---------+
> + | Chx compare +----------> | Output | ChX
> + +-----------+-+ | | Control +-->
> + . | | +---------+
> + . | | .
> + +-----------v-+ OC6REF | .
> + | Ch6 compare +---------+>
> + +-------------+
>
> - X
> - X X
> - X . . X
> - X . . X
> - X . . X
> - count X . . . . X
> - . . . .
> - . . . .
> - +---------------+
> - OC4REF | . . |
> - +-+ . . +-+
> - . +---+ .
> - OC6REF . | | .
> - +-------+ +-------+
> - +-+ +-+
> - TRGO2 | | | |
> - +-+ +---+ +---------+
> + Example with: "compare_pulse_OC4REF_r_or_OC6REF_r"::
> +
> + X
> + X X
> + X . . X
> + X . . X
> + X . . X
> + count X . . . . X
> + . . . .
> + . . . .
> + +---------------+
> + OC4REF | . . |
> + +-+ . . +-+
> + . +---+ .
> + OC6REF . | | .
> + +-------+ +-------+
> + +-+ +-+
> + TRGO2 | | | |
> + +-+ +---+ +---------+
>
> What: /sys/bus/iio/devices/triggerX/master_mode
> KernelVersion: 4.11
> @@ -91,6 +109,30 @@ Description:
> When counting down the counter start from preset value
> and fire event when reach 0.
>
Where did these come from?
> +What: /sys/bus/iio/devices/iio:deviceX/in_count_quadrature_mode_available
> +KernelVersion: 4.12
> +Contact: benjamin.gaignard@xxxxxx
> +Description:
> + Reading returns the list possible quadrature modes.
> +
> +What: /sys/bus/iio/devices/iio:deviceX/in_count0_quadrature_mode
> +KernelVersion: 4.12
> +Contact: benjamin.gaignard@xxxxxx
> +Description:
> + Configure the device counter quadrature modes:
> +
> + channel_A:
> + Encoder A input servers as the count input and B as
> + the UP/DOWN direction control input.
> +
> + channel_B:
> + Encoder B input serves as the count input and A as
> + the UP/DOWN direction control input.
> +
> + quadrature:
> + Encoder A and B inputs are mixed to get direction
> + and count with a scale of 0.25.
> +
> What: /sys/bus/iio/devices/iio:deviceX/in_count_enable_mode_available
> KernelVersion: 4.12
> Contact: benjamin.gaignard@xxxxxx
> @@ -104,6 +146,7 @@ Description:
> Configure the device counter enable modes, in all case
> counting direction is set by in_count0_count_direction
> attribute and the counter is clocked by the internal clock.
> +
> always:
> Counter is always ON.
>