Re: [RESEND PATCH] soc: ti: ti_sci_pm_domains: check for proper args count in xlate

From: santosh . shilimkar
Date: Thu Oct 29 2020 - 16:21:57 EST


Hi Arnd, olof,

On 10/29/20 2:33 AM, Tero Kristo wrote:
K2G devices still only use single parameter for power-domains property,
so check for this properly in the driver. Without this, every peripheral
fails to probe resulting in boot failure.

Fixes: efa5c01cd7ee ("soc: ti: ti_sci_pm_domains: switch to use multiple genpds instead of one")
Reported-by: Nishanth Menon <nm@xxxxxx>
Signed-off-by: Tero Kristo <t-kristo@xxxxxx>
Acked-by: Nishanth Menon <nm@xxxxxx>
Acked-by: Santosh Shilimkar <ssantosh@xxxxxxxxxx>
---
Can you please add this to your fixes queue ?
This fixes boot failures on K2Gdevices ?

drivers/soc/ti/ti_sci_pm_domains.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/soc/ti/ti_sci_pm_domains.c b/drivers/soc/ti/ti_sci_pm_domains.c
index af2126d2b2ff..8afb3f45d263 100644
--- a/drivers/soc/ti/ti_sci_pm_domains.c
+++ b/drivers/soc/ti/ti_sci_pm_domains.c
@@ -91,7 +91,7 @@ static struct generic_pm_domain *ti_sci_pd_xlate(
struct genpd_onecell_data *genpd_data = data;
unsigned int idx = genpdspec->args[0];
- if (genpdspec->args_count < 2)
+ if (genpdspec->args_count != 1 && genpdspec->args_count != 2)
return ERR_PTR(-EINVAL);
if (idx >= genpd_data->num_domains) {