Re: SIGHUP on connect

From: Michael J. Baars
Date: Fri Oct 30 2020 - 10:23:01 EST


Here, think I got it :)

Just run 'make; make run'

Thank you for your help.

On Thu, 2020-10-29 at 21:48 +0100, Bernd Petrovitsch wrote:
> Hi all!
>
> On 29/10/2020 14:10, Michael J. Baars wrote:
> [...]
> > According to manual page socket(7), SO_REUSEADDR allows for local addresses to be reused for binding. I've tested this socket option with the WAN address,
> > it
> > appears the problem is solved for both local and non-local connections.
>
> Yup.
>
> > I also found the the SO_LINGER socket option to be useful in some way. By default, SO_LINGER is set to 0, so you would think that lingering connections were
> > out
> > of the question. However, an enabled linger with a l_onoff = 1 and a l_linger = 0 seems to work a lot better than a disabled linger with a l_onoff = 0 and a
> > l_linger = 0.
> >
> > Which option would you use?
>
> I never used SO_LINGER before.
>
> From the description in `man 7 socket`, active SO_LINGER just
> makes shutdown() to block if not all data has been transmitted
> (and ACKed?).
> close() on a socket calls shutdown() automatically (unless
> the shutdown() has been already called).
>
> The timeout which you're application runs into
> applies after shutting down/closing the connection.
>
> MfG,
> Bernd

Attachment: so_reuseaddr and so_linger.tar.xz
Description: application/xz-compressed-tar