Hi Wolfram,Yes, the datasheet has a flowchart for slave mode and it shows for a write only RX_FULL interrupt followed by read from IC_DATA_CMD to retrieve received byte. Which I believe won't occur if there is no incoming data byte and only STOP_DET happens as you have observed. The flowchart however doesn't include the STOP_DET flow.
dev->status can be used to record the current state, especially Designware
I2C controller has no interrupts to identify a write-request. This patch
Just double-checking: the designware HW does not raise an interrupt when
its own address + RW bit has been received?
Not exactly. There're an interrupt state name "RD_REQ" but no one named
like "WR_REQ".
For read-request, the slave will get a RD_REQ interrupt.
For write-request, the slave won't be interrupted until data arrived to
trigger interrupt "RX_FULL".
I tried to use GPIO to simulate an I2C master. I only sent its own
address + W bit without any data and then I got only a STOP_DET interrupt.
If I sent its own address + W bit + one byte data and then I got one
RX_FULL and a STOP_DET.
It seems the controller doesn't interrupt when RW bit is W, but R does.
What do you think, Jarkko?