[PATCH v1] Input: touchscreen: ads7846.c: fix integer overflow on Rt calculation
From: Oleksij Rempel
Date: Fri Nov 13 2020 - 06:23:42 EST
In some rare cases the 32 bit Rt value will overflow if z2 and x is max,
z1 is minimal value and x_plate_ohms is relatively high (for example 800
ohm). This would happen on some screen age with low pressure.
There are two possible fixes:
- make Rt 64bit
- reorder calculation to avoid overflow
The second variant seems to be preferable, since 64 bit calculation on
32 bit system is a bit more expensive.
Fixes: ffa458c1bd9b6f653008d450f337602f3d52a646 ("spi: ads7846 driver")
Co-Developed-by: David Jander <david@xxxxxxxxxxx>
Signed-off-by: David Jander <david@xxxxxxxxxxx>
Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx>
---
drivers/input/touchscreen/ads7846.c | 5 +++--
1 file changed, 3 insertions(+), 2 deletions(-)
diff --git a/drivers/input/touchscreen/ads7846.c b/drivers/input/touchscreen/ads7846.c
index 652d9bcfdaee..78d7159e92fe 100644
--- a/drivers/input/touchscreen/ads7846.c
+++ b/drivers/input/touchscreen/ads7846.c
@@ -993,10 +993,11 @@ static void ads7846_report_state(struct ads7846 *ts)
/* compute touch pressure resistance using equation #2 */
Rt = z2;
Rt -= z1;
- Rt *= x;
Rt *= ts->x_plate_ohms;
+ Rt = DIV_ROUND_CLOSEST(Rt, 16);
+ Rt *= x;
Rt /= z1;
- Rt = (Rt + 2047) >> 12;
+ Rt = DIV_ROUND_CLOSEST(Rt, 256);
} else {
Rt = 0;
}
--
2.28.0