Re: [PATCH v2] ima: select ima-buf template for buffer measurement
From: Mimi Zohar
Date: Fri Nov 13 2020 - 10:57:26 EST
Hi Lakshmi,
On Thu, 2020-11-12 at 12:39 -0800, Lakshmi Ramasubramanian wrote:
> The default IMA template used for all policy rules is the value set
> for CONFIG_IMA_DEFAULT_TEMPLATE if the policy rule does not specify
> a template. The default IMA template for buffer measurements should be
> 'ima-buf' - so that the measured buffer is correctly included in the IMA
> measurement log entry.
>
> With the default template format, buffer measurements are added to
> the measurement list, but do not include the buffer data, making it
> difficult, if not impossible, to validate. Including 'ima-buf'
> template records in the measurement list by default, should not impact
> existing attestation servers without 'ima-buf' template support.
>
> Initialize a global 'ima-buf' template and select that template,
> by default, for buffer measurements.
>
> Signed-off-by: Lakshmi Ramasubramanian <nramas@xxxxxxxxxxxxxxxxxxx>
Thanks! It's now queued in next-integrity-testing.
Mimi