[PATCH 5/6] iio:common:ms_sensors:ms_sensors_i2c: add support for alternative PROM layout

From: Alexandre Belloni
Date: Wed Dec 09 2020 - 18:50:38 EST


Currently, only the 112bit PROM on 7 words is supported. However the ms58xx
family also have devices with a 128bit PROM on 8 words. See AN520:
C-CODE EXAMPLE FOR MS56XX, MS57XX (EXCEPT ANALOG SENSOR), AND MS58XX SERIES
PRESSURE SENSORS and the various device datasheets.

The difference is that the CRC is the 4 LSBs of word7 instead of being the
4 MSBs of word0.

Signed-off-by: Alexandre Belloni <alexandre.belloni@xxxxxxxxxxx>
---
.../iio/common/ms_sensors/ms_sensors_i2c.c | 70 ++++++++++++++++---
1 file changed, 59 insertions(+), 11 deletions(-)

diff --git a/drivers/iio/common/ms_sensors/ms_sensors_i2c.c b/drivers/iio/common/ms_sensors/ms_sensors_i2c.c
index 872f90459e2e..d97ca3e1b1d7 100644
--- a/drivers/iio/common/ms_sensors/ms_sensors_i2c.c
+++ b/drivers/iio/common/ms_sensors/ms_sensors_i2c.c
@@ -488,21 +488,18 @@ int ms_sensors_ht_read_humidity(struct ms_ht_dev *dev_data,
EXPORT_SYMBOL(ms_sensors_ht_read_humidity);

/**
- * ms_sensors_tp_crc_valid() - CRC check function for
+ * ms_sensors_tp_crc4() - Calculate PROM CRC for
* Temperature and pressure devices.
* This function is only used when reading PROM coefficients
*
* @prom: pointer to PROM coefficients array
*
- * Return: True if CRC is ok.
+ * Return: CRC.
*/
-static bool ms_sensors_tp_crc_valid(u16 *prom)
+static u8 ms_sensors_tp_crc4(u16 *prom)
{
unsigned int cnt, n_bit;
- u16 n_rem = 0x0000, crc_read = prom[0], crc = (*prom & 0xF000) >> 12;
-
- prom[MS_SENSORS_TP_PROM_WORDS_NB - 1] = 0;
- prom[0] &= 0x0FFF; /* Clear the CRC computation part */
+ u16 n_rem = 0x0000;

for (cnt = 0; cnt < MS_SENSORS_TP_PROM_WORDS_NB * 2; cnt++) {
if (cnt % 2 == 1)
@@ -517,10 +514,55 @@ static bool ms_sensors_tp_crc_valid(u16 *prom)
n_rem <<= 1;
}
}
- n_rem >>= 12;
- prom[0] = crc_read;

- return n_rem == crc;
+ return n_rem >> 12;
+}
+
+/**
+ * ms_sensors_tp_crc_valid_112() - CRC check function for
+ * Temperature and pressure devices for 112bit PROM.
+ * This function is only used when reading PROM coefficients
+ *
+ * @prom: pointer to PROM coefficients array
+ *
+ * Return: CRC.
+ */
+static bool ms_sensors_tp_crc_valid_112(u16 *prom)
+{
+ u16 w0 = prom[0], crc_read = (w0 & 0xF000) >> 12;
+ u8 crc;
+
+ prom[0] &= 0x0FFF; /* Clear the CRC computation part */
+ prom[MS_SENSORS_TP_PROM_WORDS_NB - 1] = 0;
+
+ crc = ms_sensors_tp_crc4(prom);
+
+ prom[0] = w0;
+
+ return crc == crc_read;
+}
+
+/**
+ * ms_sensors_tp_crc_valid_128() - CRC check function for
+ * Temperature and pressure devices for 128bit PROM.
+ * This function is only used when reading PROM coefficients
+ *
+ * @prom: pointer to PROM coefficients array
+ *
+ * Return: CRC.
+ */
+static bool ms_sensors_tp_crc_valid_128(u16 *prom)
+{
+ u16 w7 = prom[7], crc_read = w7 & 0x000F;
+ u8 crc;
+
+ prom[7] &= 0xFF00; /* Clear the CRC and LSB part */
+
+ crc = ms_sensors_tp_crc4(prom);
+
+ prom[7] = w7;
+
+ return crc == crc_read;
}

/**
@@ -535,6 +577,7 @@ static bool ms_sensors_tp_crc_valid(u16 *prom)
int ms_sensors_tp_read_prom(struct ms_tp_dev *dev_data)
{
int i, ret;
+ bool valid;

for (i = 0; i < dev_data->hw->prom_len; i++) {
ret = ms_sensors_read_prom_word(
@@ -546,7 +589,12 @@ int ms_sensors_tp_read_prom(struct ms_tp_dev *dev_data)
return ret;
}

- if (!ms_sensors_tp_crc_valid(dev_data->prom)) {
+ if (dev_data->hw->prom_len == 8)
+ valid = ms_sensors_tp_crc_valid_128(dev_data->prom);
+ else
+ valid = ms_sensors_tp_crc_valid_112(dev_data->prom);
+
+ if (!valid) {
dev_err(&dev_data->client->dev,
"Calibration coefficients crc check error\n");
return -ENODEV;
--
2.28.0