[PATCH v7 net-next 14/15] net: mvpp2: set 802.3x GoP Flow Control mode
From: stefanc
Date: Tue Feb 02 2021 - 03:21:39 EST
From: Stefan Chulski <stefanc@xxxxxxxxxxx>
This patch fix GMAC TX flow control autoneg.
Flow control autoneg wrongly were disabled with enabled TX
flow control.
Signed-off-by: Stefan Chulski <stefanc@xxxxxxxxxxx>
---
drivers/net/ethernet/marvell/mvpp2/mvpp2_main.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/net/ethernet/marvell/mvpp2/mvpp2_main.c b/drivers/net/ethernet/marvell/mvpp2/mvpp2_main.c
index 06d3239..98849b0 100644
--- a/drivers/net/ethernet/marvell/mvpp2/mvpp2_main.c
+++ b/drivers/net/ethernet/marvell/mvpp2/mvpp2_main.c
@@ -6284,7 +6284,7 @@ static void mvpp2_gmac_config(struct mvpp2_port *port, unsigned int mode,
old_ctrl4 = ctrl4 = readl(port->base + MVPP22_GMAC_CTRL_4_REG);
ctrl0 &= ~MVPP2_GMAC_PORT_TYPE_MASK;
- ctrl2 &= ~(MVPP2_GMAC_INBAND_AN_MASK | MVPP2_GMAC_PCS_ENABLE_MASK);
+ ctrl2 &= ~(MVPP2_GMAC_INBAND_AN_MASK | MVPP2_GMAC_PCS_ENABLE_MASK | MVPP2_GMAC_FLOW_CTRL_MASK);
/* Configure port type */
if (phy_interface_mode_is_8023z(state->interface)) {
--
1.9.1