Re: [PATCH v2 05/17] dt_bindings: bd71828: Add clock output mode
From: Rob Herring
Date: Mon Feb 08 2021 - 21:23:54 EST
On Tue, 19 Jan 2021 09:16:23 +0200, Matti Vaittinen wrote:
> The BD71828 allows configuring the clk32kout pin mode to CMOS or
> open-drain. Add device-tree property for specifying the preferred mode.
>
> Signed-off-by: Matti Vaittinen <matti.vaittinen@xxxxxxxxxxxxxxxxx>
> ---
>
> Changes from v1:
> switched clk-mode property from string type to tristated one as
> suggested by Rob.
>
> .../devicetree/bindings/mfd/rohm,bd71828-pmic.yaml | 6 ++++++
> 1 file changed, 6 insertions(+)
>
Reviewed-by: Rob Herring <robh@xxxxxxxxxx>