Re: [PATCH V3 1/2] dt-bindings: clk: versaclock5: Add optional load capacitance property

From: Rob Herring
Date: Thu Feb 11 2021 - 10:22:26 EST


On Wed, Feb 10, 2021 at 2:40 PM Adam Ford <aford173@xxxxxxxxx> wrote:
>
> On Wed, Feb 10, 2021 at 2:18 PM Rob Herring <robh@xxxxxxxxxx> wrote:
> >
> > On Sun, Feb 07, 2021 at 12:51:38PM -0600, Adam Ford wrote:
> > > There are two registers which can set the load capacitance for
> > > XTAL1 and XTAL2. These are optional registers when using an
> > > external crystal. Since XTAL1 and XTAL2 will set to the same value,
> > > update the binding to support a single property called
> > > xtal-load-femtofarads.
> > >
> > > Signed-off-by: Adam Ford <aford173@xxxxxxxxx>
> > > ---
> > > V3: No Change
> > > V2: No Change
> > >
> > > A couple people suggested that I not use the $ref, but without it,
> > > the bindings check failed with errors.
> > >
> > > diff --git a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml
> > > index 2ac1131fd922..c268debe5b8d 100644
> > > --- a/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml
> > > +++ b/Documentation/devicetree/bindings/clock/idt,versaclock5.yaml
> > > @@ -59,6 +59,12 @@ properties:
> > > minItems: 1
> > > maxItems: 2
> > >
> > > + idt,xtal-load-femtofarads:
> > > + $ref: /schemas/types.yaml#/definitions/uint32
> >
> > Don't need a type with standard unit suffix.
>
> If I remove that line, the binding check fails.

Ah, looks like femtofarads got added to property-units.txt but not the
schemas. I'll add it, but fine to leave this as-is for now.

Reviewed-by: Rob Herring <robh@xxxxxxxxxx>

Rob