Re: [v7,2/3] arm64: dts: mt8183: Configure CPU cooling

From: Matthias Brugger
Date: Mon Mar 29 2021 - 13:12:52 EST




On 16/03/2021 08:01, Michael Kao wrote:
> From: Matthias Kaehlcke <mka@xxxxxxxxxxxx>
>
> Add two passive trip points at 68°C and 80°C for the CPU temperature.
>
> Signed-off-by: Matthias Kaehlcke <mka@xxxxxxxxxxxx>
> Signed-off-by: Michael Kao <michael.kao@xxxxxxxxxxxx>
> Tested-by: Hsin-Yi Wang <hsinyi@xxxxxxxxxxxx>

Applied to v5.12-next/dts64

Thanks.
Matthias



> ---
> arch/arm64/boot/dts/mediatek/mt8183.dtsi | 56 ++++++++++++++++++++++++
> 1 file changed, 56 insertions(+)
>
> diff --git a/arch/arm64/boot/dts/mediatek/mt8183.dtsi b/arch/arm64/boot/dts/mediatek/mt8183.dtsi
> index d3550af06408..1ad0a1d55d53 100644
> --- a/arch/arm64/boot/dts/mediatek/mt8183.dtsi
> +++ b/arch/arm64/boot/dts/mediatek/mt8183.dtsi
> @@ -13,6 +13,7 @@
> #include <dt-bindings/power/mt8183-power.h>
> #include <dt-bindings/reset-controller/mt8183-resets.h>
> #include <dt-bindings/phy/phy.h>
> +#include <dt-bindings/thermal/thermal.h>
> #include "mt8183-pinfunc.h"
>
> / {
> @@ -678,6 +679,61 @@
> polling-delay = <500>;
> thermal-sensors = <&thermal 0>;
> sustainable-power = <5000>;
> +
> + trips {
> + threshold: trip-point@0 {
> + temperature = <68000>;
> + hysteresis = <2000>;
> + type = "passive";
> + };
> +
> + target: trip-point@1 {
> + temperature = <80000>;
> + hysteresis = <2000>;
> + type = "passive";
> + };
> +
> + cpu_crit: cpu-crit {
> + temperature = <115000>;
> + hysteresis = <2000>;
> + type = "critical";
> + };
> + };
> +
> + cooling-maps {
> + map0 {
> + trip = <&target>;
> + cooling-device = <&cpu0
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>,
> + <&cpu1
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>,
> + <&cpu2
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>,
> + <&cpu3
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>;
> + contribution = <3072>;
> + };
> + map1 {
> + trip = <&target>;
> + cooling-device = <&cpu4
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>,
> + <&cpu5
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>,
> + <&cpu6
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>,
> + <&cpu7
> + THERMAL_NO_LIMIT
> + THERMAL_NO_LIMIT>;
> + contribution = <1024>;
> + };
> + };
> };
>
> /* The tzts1 ~ tzts6 don't need to polling */
>