Re: [PATCH v8 2/8] pwm: pca9685: Support hardware readout

From: Uwe Kleine-König
Date: Mon Apr 12 2021 - 12:21:20 EST


Hello Clemens,

On Mon, Apr 12, 2021 at 03:27:39PM +0200, Clemens Gruber wrote:
> Implement .get_state to read-out the current hardware state.
>
> The hardware readout may return slightly different values than those
> that were set in apply due to the limited range of possible prescale and
> counter register values.
>
> Also note that although the datasheet mentions 200 Hz as default
> frequency when using the internal 25 MHz oscillator, the calculated
> period from the default prescaler register setting of 30 is 5079040ns.
>
> Signed-off-by: Clemens Gruber <clemens.gruber@xxxxxxxxxxxx>

Reviewed-by: Uwe Kleine-König <u.kleine-koenig@xxxxxxxxxxxxxx>

Best regards
Uwe

--
Pengutronix e.K. | Uwe Kleine-König |
Industrial Linux Solutions | https://www.pengutronix.de/ |

Attachment: signature.asc