Re: [PATCH v2] net: phy: marvell: fix detection of PHY on Topaz switches

From: Andrew Lunn
Date: Mon Apr 12 2021 - 13:45:01 EST


On Mon, Apr 12, 2021 at 06:57:39PM +0200, Pali Rohár wrote:
> Since commit fee2d546414d ("net: phy: marvell: mv88e6390 temperature
> sensor reading"), Linux reports the temperature of Topaz hwmon as
> constant -75°C.
>
> This is because switches from the Topaz family (88E6141 / 88E6341) have
> the address of the temperature sensor register different from Peridot.
>
> This address is instead compatible with 88E1510 PHYs, as was used for
> Topaz before the above mentioned commit.
>
> Create a new mapping table between switch family and PHY ID for families
> which don't have a model number. And define PHY IDs for Topaz and Peridot
> families.
>
> Create a new PHY ID and a new PHY driver for Topaz's internal PHY.
> The only difference from Peridot's PHY driver is the HWMON probing
> method.
>
> Prior this change Topaz's internal PHY is detected by kernel as:
>
> PHY [...] driver [Marvell 88E6390] (irq=63)
>
> And afterwards as:
>
> PHY [...] driver [Marvell 88E6341 Family] (irq=63)
>
> Signed-off-by: Pali Rohár <pali@xxxxxxxxxx>
> BugLink: https://github.com/globalscaletechnologies/linux/issues/1
> Fixes: fee2d546414d ("net: phy: marvell: mv88e6390 temperature sensor reading")
> Reviewed-by: Marek Behún <kabel@xxxxxxxxxx>

Reviewed-by: Andrew Lunn <andrew@xxxxxxx>

Andrew