Re: [PATCH v8 1/8] pwm: pca9685: Switch to atomic API
From: Uwe Kleine-König
Date: Sat Apr 17 2021 - 11:37:39 EST
On Mon, Apr 12, 2021 at 03:27:38PM +0200, Clemens Gruber wrote:
> The switch to the atomic API goes hand in hand with a few fixes to
> previously experienced issues:
> - The duty cycle is no longer lost after disable/enable (previously the
> OFF registers were cleared in disable and the user was required to
> call config to restore the duty cycle settings)
> - If one sets a period resulting in the same prescale register value,
> the sleep and write to the register is now skipped
> - Previously, only the full ON bit was toggled in GPIO mode (and full
> OFF cleared if set to high), which could result in both full OFF and
> full ON not being set and on=0, off=0, which is not allowed according
> to the datasheet
> - The OFF registers were reset to 0 in probe, which could lead to the
> forbidden on=0, off=0. Fixed by resetting to POR default (full OFF)
I didn't recheck all details, but the patch is definitively an
improvement, so:
Acked-by: Uwe Kleine-König <u.kleine-koenig@xxxxxxxxxxxxxx>
Best regards
Uwe
--
Pengutronix e.K. | Uwe Kleine-König |
Industrial Linux Solutions | https://www.pengutronix.de/ |
Attachment:
signature.asc