Re: [RFC PATCH v1 8/9] net: phy: micrel: ksz886x/ksz8081: add cabletest support

From: Oleksij Rempel
Date: Mon May 10 2021 - 05:07:09 EST


On Wed, May 05, 2021 at 02:47:19PM +0200, Andrew Lunn wrote:
> On Wed, May 05, 2021 at 11:20:24AM +0200, Oleksij Rempel wrote:
> > This patch support for cable test for the ksz886x switches and the
> > ksz8081 PHY.
> >
> > The patch was tested on a KSZ8873RLL switch with following results:
> >
> > - port 1:
> > - cannot detect any distance
> > - provides inverted values
> > (Errata: DS80000830A: "LinkMD does not work on Port 1",
> > http://ww1.microchip.com/downloads/en/DeviceDoc/KSZ8873-Errata-DS80000830A.pdf)
> > - Reports "short" on open or ok.
> > - Reports "ok" on short.
>
> Quite broken. Distance is optional, simply don't report it. Status is
> harder. Reporting ETHTOOL_A_CABLE_RESULT_CODE_OK should really mean
> the cable is O.K. If you cannot tell open from O.K, i would return
> ETHTOOL_A_CABLE_RESULT_CODE_UNSPEC.
>

Yes, patch "net: phy: micrel: add patch for erratas on port1" provides
a flag to return -ENOTSUPP on this port.

Is it acceptable way? Should I squash this patches?

Regards,
Oleksij
--