Re: [PATCH v6 01/17] dt-bindings: mfd: axp20x: Add AXP305 compatible (plus optional IRQ)

From: Andre Przywara
Date: Sat May 22 2021 - 20:07:04 EST


On Sat, 22 May 2021 09:46:23 -0500
Samuel Holland <samuel@xxxxxxxxxxxx> wrote:

> On 5/19/21 5:41 AM, Andre Przywara wrote:
> > The AXP305 PMIC used in AXP805 seems to be fully compatible to the
> ^^^^^^^^^^^^^^
> Typo? Do you mean "used with the H616 SoC"?

Ouch, yes. And even more embarrassingly Chen-Yu pointed that out already
in the previous version. Same for the compatible string.

Thanks for having a look!

Cheers,
Andre

>
> > AXP805 PMIC, so add the proper chain of compatible strings.
> >
> > Also at least on one board (Orangepi Zero2) there is no interrupt line
> > connected to the CPU, so make the "interrupts" property optional.
> >
> > Signed-off-by: Andre Przywara <andre.przywara@xxxxxxx>
> > ---
> > Documentation/devicetree/bindings/mfd/axp20x.txt | 3 ++-
> > 1 file changed, 2 insertions(+), 1 deletion(-)
> >
> > diff --git a/Documentation/devicetree/bindings/mfd/axp20x.txt b/Documentation/devicetree/bindings/mfd/axp20x.txt
> > index 4991a6415796..4fd748101e3c 100644
> > --- a/Documentation/devicetree/bindings/mfd/axp20x.txt
> > +++ b/Documentation/devicetree/bindings/mfd/axp20x.txt
> > @@ -26,10 +26,10 @@ Required properties:
> > * "x-powers,axp803"
> > * "x-powers,axp806"
> > * "x-powers,axp805", "x-powers,axp806"
> > + * "x-powers,axp803", "x-powers,axp805", "x-powers,axp806"
> ^^^^^^
> This should be x-powers,axp305.
>
> Regards,
> Samuel
>
> > * "x-powers,axp809"
> > * "x-powers,axp813"
> > - reg: The I2C slave address or RSB hardware address for the AXP chip
> > -- interrupts: SoC NMI / GPIO interrupt connected to the PMIC's IRQ pin
> > - interrupt-controller: The PMIC has its own internal IRQs
> > - #interrupt-cells: Should be set to 1
> >
> > @@ -43,6 +43,7 @@ more information:
> > AXP20x/LDO3: software-based implementation
> >
> > Optional properties:
> > +- interrupts: SoC NMI / GPIO interrupt connected to the PMIC's IRQ pin
> > - x-powers,dcdc-freq: defines the work frequency of DC-DC in KHz
> > AXP152/20X: range: 750-1875, Default: 1.5 MHz
> > AXP22X/8XX: range: 1800-4050, Default: 3 MHz
> >
>
>