From: Liam Beguin <lvb@xxxxxxxxxx>
An ADC is often used to measure other quantities indirectly. This
binding describe one cases, the measurement of a temperature through
the voltage across an RTD resistor such as a PT1000.
Signed-off-by: Liam Beguin <lvb@xxxxxxxxxx>
---
.../iio/afe/temperature-sense-rtd.yaml | 65 +++++++++++++++++++
MAINTAINERS | 1 +
2 files changed, 66 insertions(+)
create mode 100644 Documentation/devicetree/bindings/iio/afe/temperature-sense-rtd.yaml
diff --git a/Documentation/devicetree/bindings/iio/afe/temperature-sense-rtd.yaml b/Documentation/devicetree/bindings/iio/afe/temperature-sense-rtd.yaml
new file mode 100644
index 000000000000..4798eda6e533
--- /dev/null
+++ b/Documentation/devicetree/bindings/iio/afe/temperature-sense-rtd.yaml
@@ -0,0 +1,65 @@
+# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
+%YAML 1.2
+---
+$id: http://devicetree.org/schemas/iio/afe/temperature-sense-rtd.yaml#
+$schema: http://devicetree.org/meta-schemas/core.yaml#
+
+title: Temperature Sense RTD
+
+maintainers:
+ - Liam Beguin <lvb@xxxxxxxxxx>
+
+description: |
+ When an io-channel measures the output voltage across an RTD such as a
+ PT1000, the interesting measurement is almost always the corresponding
+ temperature, not the voltage output. This binding describes such a circuit.
+
+properties:
+ compatible:
+ const: temperature-sense-rtd
+
+ io-channels:
+ maxItems: 1
+ description: |
+ Channel node of a voltage io-channel.
+
+ '#io-channel-cells':
+ const: 1
+
+ excitation-current-microamp:
+ description: The current fed through the RTD sensor.
+
+ alpha-micro-ohms-per-ohm-celsius:
+ description: |
+ Linear approximation of the resistance versus temperature relationship
+ between 0 and 100 degrees Celsius.
+
+ Pure platinum has an alpha of 3925. Industry standards such as IEC60751
+ and ASTM E-1137 specify an alpha of 3850.
+
+ r-naught-ohms:
+ description: |
+ Resistance of the sensor at 0 degrees Celsius.
+ Common values are 100 for PT100 and 1000 for PT1000.
+
+additionalProperties: false
+required:
+ - compatible
+ - io-channels
+ - excitation-current-microamp
+ - alpha-micro-ohms-per-ohm-celsius
+ - r-naught-ohms
+
+examples:
+ - |
+ pt1000_1: iio-rescale0 {
+ compatible = "temperature-sense-rtd";
+ #io-channel-cells = <1>;
+ io-channels = <&temp_adc1 0>;
+
+ excitation-current-microamp = <1000>;
+ alpha-micro-ohms-per-ohm-celsius = <3908>;
+ r-naught-ohms = <1000>;
+ };
+
+...
diff --git a/MAINTAINERS b/MAINTAINERS
index d3ab0ccc34ab..a7279af85adb 100644
--- a/MAINTAINERS
+++ b/MAINTAINERS
@@ -8721,6 +8721,7 @@ L: linux-iio@xxxxxxxxxxxxxxx
S: Maintained
F: Documentation/devicetree/bindings/iio/afe/current-sense-amplifier.yaml
F: Documentation/devicetree/bindings/iio/afe/current-sense-shunt.yaml
+F: Documentation/devicetree/bindings/iio/afe/temperature-sense-rtd.yaml
F: Documentation/devicetree/bindings/iio/afe/voltage-divider.yaml
F: drivers/iio/afe/iio-rescale.c
--
2.30.1.489.g328c10930387