[PATCH AUTOSEL 5.12 21/39] net: phy: dp83867: perform soft reset and retain established link
From: Sasha Levin
Date: Mon Jun 21 2021 - 13:53:22 EST
From: Praneeth Bajjuri <praneeth@xxxxxx>
[ Upstream commit da9ef50f545f86ffe6ff786174d26500c4db737a ]
Current logic is performing hard reset and causing the programmed
registers to be wiped out.
as per datasheet: https://www.ti.com/lit/ds/symlink/dp83867cr.pdf
8.6.26 Control Register (CTRL)
do SW_RESTART to perform a reset not including the registers,
If performed when link is already present,
it will drop the link and trigger re-auto negotiation.
Signed-off-by: Praneeth Bajjuri <praneeth@xxxxxx>
Signed-off-by: Geet Modi <geet.modi@xxxxxx>
Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx>
Signed-off-by: Sasha Levin <sashal@xxxxxxxxxx>
---
drivers/net/phy/dp83867.c | 6 +-----
1 file changed, 1 insertion(+), 5 deletions(-)
diff --git a/drivers/net/phy/dp83867.c b/drivers/net/phy/dp83867.c
index 9bd9a5c0b1db..6bbc81ad295f 100644
--- a/drivers/net/phy/dp83867.c
+++ b/drivers/net/phy/dp83867.c
@@ -826,16 +826,12 @@ static int dp83867_phy_reset(struct phy_device *phydev)
{
int err;
- err = phy_write(phydev, DP83867_CTRL, DP83867_SW_RESET);
+ err = phy_write(phydev, DP83867_CTRL, DP83867_SW_RESTART);
if (err < 0)
return err;
usleep_range(10, 20);
- /* After reset FORCE_LINK_GOOD bit is set. Although the
- * default value should be unset. Disable FORCE_LINK_GOOD
- * for the phy to work properly.
- */
return phy_modify(phydev, MII_DP83867_PHYCTRL,
DP83867_PHYCR_FORCE_LINK_GOOD, 0);
}
--
2.30.2