RE: [PATCH] scsi: BusLogic: use %X for u32 sized integer rather than %lX
From: David Laight
Date: Mon Aug 02 2021 - 04:11:52 EST
From: Colin King
> Sent: 30 July 2021 10:51
>
> From: Colin Ian King <colin.king@xxxxxxxxxxxxx>
>
> An earlier fix changed the print format specifier for adapter->bios_addr
> to use %lX however the integer is a u32 so the fix was wrong. Fix this
> by using the correct %X format specifier.
Is that right?
I bet one 32bit arch defines u32 as long.
David
-